Customer Service Troubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions

Before you call for service…

Troubleshooting Tips

Problem

 

Possible Causes

What To Do

 

 

 

 

 

Rumbling noise

 

Scale and sediment

Clean tank.

 

 

in tank.

 

 

 

 

 

 

Relief valve

 

Pressure build up

This is an unacceptable condition and must be

producing popping

 

caused by thermal

corrected. Contact the water supplier or plumbing

noise or draining

 

expansion to a

contractor on how to correct this. Do not plug the

 

 

closed system.

relief valve outlet.

 

 

 

 

 

Not enough or

 

Water usage may have

Wait for the water heater to recover after an abnormal

no hot water

 

exceeded the capacity

demand.

 

 

of the water heater.

 

 

 

 

 

 

 

 

Low gas pressure.

Check gas supply pressure and manifold pressure.

 

 

 

 

 

 

 

The pilot may be out.

Check the pilot. If necessary, relight using the

 

 

 

 

instructions in the “Lighting The Water Heater” section

 

 

 

 

of this manual.

 

 

 

 

 

 

 

The gas control (thermostat)

See the “Water Temperature Setting of The Water

 

 

 

may be set too low.

Heater” section of this manual.

 

 

 

 

 

 

 

Leaking or open hot water

Make sure all faucets are closed.

 

 

faucets.

 

 

 

 

 

 

 

Combustion Shutoff System

Contact a qualified service technician.

 

 

tripped.

 

 

 

 

 

Water is too hot

 

The gas control (thermostat)

See the “Water Temperature Setting of The Water

 

 

is set too high.

Heater” section of this manual.

 

 

 

 

 

 

Gas control (thermostat).

Contact a qualified service technician to replace the

 

 

 

Defective

gas control (thermostat).

 

 

 

 

Pilot Lights, but

 

Combustion Shutoff System

Contact a qualified service technician.

Burner will not

 

tripped.

 

stay lit

 

 

 

 

 

 

 

 

 

!CAUTION: For your safety DO NOT attempt repair of gas piping, gas control (gas control (thermostat)), burners, vent connectors or other safety devices. Refer repairs to qualified service personnel.