26-5/8"
12"
1/2"
8-7/16"
Countertop
Level
22-3/4"
23-1/4"
4" to Center Line
of Gas Inlet
on the Left
Allow Additional Clearance
Below the Burner Box for
Gas Connections
2-1/2"
Cabinet Face - Projecting Control Panel
Cabinet Face - Flush Control Panel
1/2"
12" High
Backsplash
22"
High
Back
22" High
Backsplash
with Shelf
1/2" Above Adjacent
Countertops.
Front Projects Outward as Shown
From Standard Depth Cabinets.
Cooktop
1/2" Above Adjacent
Countertops.
Front Flush With Cabinets - a Minimum
of 25-3/4" Cabinet Depth Required
Flush With Cabinet Front
Cooktop

ADVANCE PLANNING

Refer to “Dimensions and Clearances” for appropriate
placement and necessary clearances when planning
the installation.
• Cabinetry cannot be installed directly above the
cooktop.
• We recommend the installation of a vent hood above
the cooktop surface.
– The vent hood must be at least 24" deep.
– The vent hood must be at least the same width as
the cooktop.
– For 48" models, we recommend the vent hood
blower be 1200 CFM.
– For 36" models, we recommend the vent hood
blower be 600 CFM.
• Refer to hood installation instructions for height
dimensions.
• Working areas adjacent to the cooktop should have
18" minimum clearance between countertop and
cabinet bottom.
• Clearance between cooktop and side wall or
combustible material must be at least 12" on
each side.
• These cooktops require 8" free space below the
countertop to house the burner box. Additional
clearance is required below the burner box for the
gas regulator and connections. Connections should
be routed to limit interference with drawers or other
cabinetry features.
• Allow 12" min. clearance at the back to combustible
materials.
• Allow 36" min. above the cooking surface to
combustible materials.
• Installation must conform with local codes. In the
absence of local codes, the gas cooktop must comply
with the National Fuel Gas Code, ANSI Z223.1/NFPA.54,
latest edition. In Canada, installation must conform
with the current Natural Gas Installation Code,
CAN/CGA-B149.1 or the current Propane Installation
Code, CAN/CGA-B149.2, and with local codes where
applicable. This cooktop has been design-certified by
CSA International according to ANSI Z21.1, latest
edition and Canadian Gas Association according to
CAN/CGA-1.1 latest edition.
5

INSTALLATION OPTIONS

These cooktops can be installed in standard 24" or
deeper 25" cabinets.
• In 24" deep cabinets, the front of the cooktop will
project approximately 1-7/8" beyond the front of the
countertop.
• In 25" deep cabinets, the cooktop will be flush with
the front of the countertop.
• The stainless surface of the cooktop will be 1/2"
higher than adjacent countertop.
• Cooktop fits flush to rear of cutout; no additional
support is required.
Installation Preparation