Questions?

Use this problem solver!

 

 

The Problem Solver

 

 

 

 

 

 

 

Professional Island Range Hood

 

 

 

 

PROBLEM

POSSIBLE CAUSE

 

 

 

 

 

FAN AND LIGHTS DO

• The hood was never electrically connected by the installer/

 

NOT OPERATE WHEN

electrician/builder. Call the electrician/installer/builder to

 

THE SWITCHES ARE

complete the installation. This is not covered by warranty.

 

TURNED ON

• A fuse may be blown or a circuit breaker tripped. Replace the fuse

 

 

 

 

or reset the circuit breaker.

 

 

 

 

 

THE BLOWER DOES

• The blower motor wire harness was not connected or was not

 

NOT WORK BUT

connected properly by the installer/electrician/builder to its mating

 

THE LIGHTS DO

connector located inside the hood on the top surface, to the left of

 

 

the blower assembly.

 

 

1. Switch power off at service panel and lock the service

 

 

disconnecting means to prevent power from being switched on

 

 

accidentally. When the service disconnecting means cannot be

 

 

locked, securely fasten a prominent warning device, such as

 

 

a tag, to the service panel.

 

 

2. Remove the filters and locate the blower wire harness connector.

 

 

Is it plugged into its mating connector?

 

 

3. If no, plug the blower motor connector into its mating connector

 

 

on the top of the hood. Switch the power back on. Check to see

 

 

if the fan now works.

 

 

4. If no, check the circuit breaker/fuse. If it is blown/tripped,

 

 

replace/reset it. Does the blower work now? If no, call GE

 

 

for service.

 

 

 

 

 

THE BLOWER FAILS

• Many factors could be the root cause for reduced air-flow.

 

TO EXHAUST THE

1. Installation could be the problem: Your hood was designed to

 

SMOKE/STEAM/

 

meet specific ducting requirements. Refer to the Installation

 

ODORS ADEQUATELY

 

Instructions or if you do not have them, go to ge.com.

 

 

 

 

If your duct length exceeds the manufacturer’s requirements,

 

 

hood performance will suffer. Air-flow will also be reduced if the

 

 

house duct work is too small or there are too many elbows in the

 

 

system. Contact your installer or builder.

 

 

2. Obstruction in duct work could be the problem: Make sure

 

 

nothing is blocking the vent (bird nests or kinks in the duct work).

 

 

3. Damper blade may not be opening. Make sure the tape is removed

 

 

from the damper blades and that it swings open freely.

 

 

4. Damper blade on Wall or Roof Cap may not be opening. Contact

 

 

your builder so they can make sure the damper swings open freely.

 

 

5. Dirty filters/baffles—make sure filters (and all hood surfaces) are

 

 

kept clean of grease and dirt.

 

 

 

 