Monogram.™
ZDP48L4GWSS—48" Professional Ranges
Dimensions and Specifications (in inches)
ZX22B48WSS
ZX12B48WSS
These ranges are factory set for either natural gas or liquid propane gas.
48" Natural Gas Model:
48" Liquid Propane Gas Model:
Accessory Requirements:
All models require the installation of a backguard. A backguard should be ordered at the same time as the range. Both must be on site at the time of installation.
Order one backguard for 48" models:
ZX1B48WSS
Available
Backguards
12"
Advance Planning:
Refer to dimensional drawings for appropriate placement and necessary clearances when planning
the installation.
•Cabinetry cannot be installed directly above the range.
•This range requires the installation of a vent hood, 30" to 36" above the surface.
–The vent hood must be at least 24" deep.
–The vent hood must be the same width as the range.
–The vent hood blower should provide at least 800 CFM and up to 1200 CFM.
–When installing a range that includes a grill, select a blower on the high end of the CFM recommendation.
•Working areas adjacent to the range should have 18" minimum clearance between countertop and cabinet bottom.
•Clearance between range and side wall or combustible material must be at least 12" on each side.