Monogram.™
ZIC360NM – GE Monogram 36"
The Installation Space
The finished cabinet width must be 35-1/2".
Finished Width
|
|
|
|
|
|
|
|
|
| Wall View | |||||||
|
|
|
|
| 7" |
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 10" |
|
|
| Electrical |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| Area |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| 24" Cutout Depth |
|
|
| Floor to Bottom | |||||||||||
Finished |
|
|
|
|
| of Electrical | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Opening |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 5" |
|
|
| Water Supply |
| 5" |
|
| |||||
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| 3 1/2" |
|
| 3 1/2" |
|
|
| |||||||||
|
|
|
Dimensions and Clearances
Water and Electrical Locations
Electrical and water supply must be located as shown.
The cutout depth must be 24"
Designed for industry standard flush installation. The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation.
Cutout depth beneath a soffit
When installed beneath a soffit, the soffit cannot exceed the 24" installation depth shown. The top case trim overlaps the bottom of the soffit.
Frameless Cabinets
The case trim overlaps cabinets at the top and sides. Therefore, frameless cabinets may require filler strips to prevent interference with cabinet door swing. The opening must allow for filler strips.
Additional Specifications
•A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded
Note: GFI (grounded fault interrupter) is not recommended.
35"
Case Width
*84" From Floor to Top Frame
*Shipping height. The refrigerator can be adjusted to fit into a cutout that is
•Water line can enter the opening through the floor or back wall. The water line should be 1/4" O.D. copper tubing between the cold water line and water connection location, long enough to extend to the front of the refrigerator. Installation of an easily accessible shut off valve in the water line is recommended.
Optional Panel Kits:
•ZPBC360: Black Panel Kit
•ZPWC360: White Panel Kit
•ZPSC360: Stainless Steel Panel Kit
Optional Custom Trim Kits:
•ZKHCSS2: Tubular Stainless Steel handles
•ZUG2: Unified Grille Kit
36" Frame to Frame
Width
Product Clearances
These refrigerators are equipped with a 2 position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted.
90° Door Swing
90°
4" Minimum
to Wall
130° Door Swing
25" Minimum to Wall
130°
Allow 25" minimum clearance for a full 130° door swing. Allow 15" for pan removal.
4" minimum clearance is required when door swing is adjusted to 90°. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted.
For answers to your Monogram,® GE Profile™ or |
|
GE appliance questions, visit our website at | Listed by |
GEAppliances.com or call | Underwriters |
R | Laboratories |
Specification Revised 8/02
GE Answer Center® service, 800.626.2000. |