GE Monogram ZICS360NX dimensions Door Swing Clearances, Product Dimensions

Models: ZICS360NX

1 2
Download 2 pages 36.74 Kb
Page 1
Image 1
ZICS360NX

ZICS360NX

GE Monogram® 36” Built-In Bottom Freezer Refrigerator

Dimensions and Installation Information (in inches) The Installation Space

The finished cutout width must be 35-1/2".

Door Swing Clearances

The installation must allow for clearances to adjacent walls or cabinets. These refrigerators are equipped with a 2-position

35-1/2"

Finished Width

2-5/16"

Wall View

door stop. The factory-set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted.

 

 

 

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10"

 

 

 

Electrical

 

84-1/2" max

 

 

 

 

 

 

 

 

 

 

Area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

83-1/2" min

 

 

24" Cutout Depth

 

Finished

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opening

 

 

 

 

 

 

Cold Water

 

 

 

 

 

5"

 

 

 

 

 

Supply

 

5"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 1/2"

3 1/2"

 

 

75" From Floor to Bottom of Electrical Area

Note: Icemaker water connectio Door Swing Clearances is at the front.

130° Door Swing

The cutout depth must be 24" 25" Product Dimensions Min. to

Wall

23-7/8"

90° Door Swing Behind Frame

36-3/4"

The cutout depth must be 24"

The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation.

130°

90°

4" Min. to Wall 5" Min. for Professional Models

The cutout depth beneath a soffit:When installed beneath a soffit, the soffit cannot exceed the 24" installation depth shown. The top case trim overlaps the bottom of the soffit.

Electrical: A 115V, 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on rear wall as shown.

Note: GFI (ground fault interrupter) is not recommended.

Water Line: All models are equipped with an automatic icemaker. The water line can enter the opening through the floor or back wall. Route GE SmartConnectKit or 1/4" O.D. copper tubing between the cold water line and the water connection location at the front of the refrigerator. The

installation of an easily accessible shut-off valve in the water

line is required.

*Shipping Height. The

Product Dimensions

refrigerator can be adjusted

35"

Case Depth:

to fit into a cutout that is

Case Width

25-3/8" Framed Models

 

25-3/4" Stainless Steel Models

83-1/2" min. to 84-1/2" max.

 

 

Allow 25" minimum clearances for a full 130° door swing. Allow 15" for pan removal.

4" minimum clearance is required when the door swing is adjusted to 90°. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted.

See door swing illustrations to determine interaction with adjacent cabinets or countertops.

ZUG2, ZUGSS2 Unified Grille Panel Kit

If you are installing two refrigerators side by side, the installation space must be 71-1/2" wide.

Note: Additional cutout width may be required when side panels are used. Add side panel thickness to the finished cutout to calculate rough-in width.

The water and electrical locations for each product must be located as shown.

A separate 115V, 60Hz., 15 or 20 amp power supply is recommended for each product.

71-1/2" Finished Width

 

*84" From

height.

*83-1/2"

The top case trim at the front

Floor to

at

Top Frame

is 1/2" higher and will overlap

Rear

 

 

 

upper cabinetry or soffit.

36"

 

Use leveling legs and wheels

 

for a maximum 1" height

Frame to Frame Width

Depth Including Handles:

 

adjustment.

26-7/8" Framed Models

 

27-3/4" Stainless Steel Models

28-11/16" Professional Models

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

ZUG2, ZUGSS2 Unified Grille Panel Kit2-5/16"Electrical

10"

84-1/2" max Specification Created 6/08 24" Cutout

83-1/2" min Depth Finished

Opening

5" Manual background Water Supply

Manual backgroundManual background 26" 3-1/2"

 

 

 

 

 

 

 

 

24-3/16"

 

Wall View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75" From

 

 

 

 

 

 

 

 

 

 

 

 

 

Floor to Bottom

 

 

 

 

 

 

 

 

 

 

 

 

 

of Electrical

 

Water Supply

 

5"

Area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26"

 

 

3-1/2"

 

 

 

 

 

 

 

 

 

 

 

 

Listed by Underwriters Laboratories

Specification Created 6/08

110114

Page 1
Image 1
GE Monogram ZICS360NX dimensions Door Swing Clearances, Product Dimensions, The cutout depth must be