ZICS360NX
GE Monogram® 36”
Dimensions and Installation Information (in inches) The Installation Space
The finished cutout width must be
Door Swing Clearances
The installation must allow for clearances to adjacent walls or cabinets. These refrigerators are equipped with a
Finished Width |
Wall View
door stop. The
|
|
|
|
|
|
|
|
|
|
|
| 6" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| 10" |
|
|
| Electrical |
| ||||
|
|
|
|
|
|
|
|
|
| Area |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| 24" Cutout Depth |
| |||||||||||
Finished |
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Opening |
|
|
|
|
|
| Cold Water |
|
| |||||
|
|
| 5" |
|
|
|
|
| Supply |
| 5" | |||
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| 3 1/2" | 3 1/2" | |||||||||||
|
|
75" From Floor to Bottom of Electrical Area
Note: Icemaker water connectio is at the front.
130° Door Swing
25" Min. to
Wall
90° Door Swing Behind Frame
The cutout depth must be 24"
The refrigerator will project forward, slightly beyond adjacent cabinetry, depending on your installation.
130°
90°
4" Min. to Wall 5" Min. for Professional Models
The cutout depth beneath a soffit:When installed beneath a soffit, the soffit cannot exceed the 24" installation depth shown. The top case trim overlaps the bottom of the soffit.
Electrical: A 115V, 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded
Note: GFI (ground fault interrupter) is not recommended.
Water Line: All models are equipped with an automatic icemaker. The water line can enter the opening through the floor or back wall. Route GE SmartConnect™ Kit or 1/4" O.D. copper tubing between the cold water line and the water connection location at the front of the refrigerator. The
installation of an easily accessible | |||
line is required. | *Shipping Height. The | ||
Product Dimensions | |||
refrigerator can be adjusted | |||
35" | Case Depth: | ||
to fit into a cutout that is | |||
Case Width | |||
| |||
|
|
Allow 25" minimum clearances for a full 130° door swing. Allow 15" for pan removal.
•4" minimum clearance is required when the door swing is adjusted to 90°. If the 90° door stop position is used, pan access is maintained, but pan removal is restricted.
•See door swing illustrations to determine interaction with adjacent cabinets or countertops.
ZUG2, ZUGSS2 Unified Grille Panel Kit
•If you are installing two refrigerators side by side, the installation space must be
Note: Additional cutout width may be required when side panels are used. Add side panel thickness to the finished cutout to calculate
•The water and electrical locations for each product must be located as shown.
•A separate 115V, 60Hz., 15 or 20 amp power supply is recommended for each product.
| *84" From | height. | |
The top case trim at the front | |||
Floor to | |||
at | Top Frame | is 1/2" higher and will overlap | |
Rear |
| ||
|
| upper cabinetry or soffit. | |
36" |
| Use leveling legs and wheels | |
| for a maximum 1" height | ||
Frame to Frame Width | |||
Depth Including Handles: |
| adjustment. | |
|
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
10"
Opening
5" Water Supply
26"
|
|
|
|
|
|
|
|
| Wall View | ||||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| 6" |
|
|
|
| |||
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10" |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| 75" From |
|
|
|
|
|
|
|
|
|
|
|
|
| Floor to Bottom |
|
|
|
|
|
|
|
|
|
|
|
|
| of Electrical |
| Water Supply |
| 5" | Area | |||||||||
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 26" |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Listed by Underwriters Laboratories
Specification Created 6/08 | 110114 |