Genelec 1094A, 1092A manual System, Specifications, Crossover, Section, Amplifier, Input, Output

Models: 1092A 1094A

1 8
Download 8 pages 10.51 Kb
Page 8
Image 8
SYSTEM

SYSTEM

 

 

 

SPECIFICATIONS

1094A

1092A

Free field frequency response

 

 

of system (± 2.5 dB):

 

29 - 80 Hz

33 - 80 Hz

Maximum short term sine wave

 

 

acoustic output in half space,

 

 

averaged from 35 Hz to 85 Hz

 

 

@ 1m:

 

>120 dB SPL

>115 dB SPL

Self generated noise level in free

 

 

field @ 1m on axis (A-weighted)

< 10 dB

< 10 dB

Harmonic distortion at 100 dB SPL

 

 

@ 1m on axis in half space

 

 

(30...100 Hz):

 

< 3%

< 4%

Drivers:

 

385 mm

2 x 210 mm

 

 

(15")

(2 x 8")

Weight:

 

50 kg

30 kg

 

 

(110 lb)

(66 lb)

Dimensions:

Height

739 mm

615 mm

 

 

(291/16")

(24 3/16")

 

Width

468 mm

320 mm

 

 

( 18 7/16")

(12 5/8")

 

Depth

620 mm

510 mm

 

 

(247/16")

(201/16")

CROSSOVER

 

 

 

SECTION

 

Both Models

 

 

 

Subsonic filter (18 dB/octave)

 

 

below:

 

29 Hz

33 Hz

Crossover frequency, (sub/main monitors)

85 Hz

Crossover frequency, (sub input channel)

Full band/85 Hz

Crossover acoustical slope

 

 

Lowpass:

 

 

28 dB/octave

Highpass:

 

 

12 dB/octave

Midband rejection, freq. > 400 Hz:

 

> 50 dB

Bass roll-off control operating

 

 

range in 2 dB steps:

 

from 0 to -6 dB @ 33 Hz

Phase matching control in 90° steps: from 0° to -270° @ 85 Hz

Genelec Oy, Olvitie 5

FIN - 74100 IISALMI, FINLAND

Phone: +358 - 17 - 813 311

Telefax: +358 - 17 - 812 267

Web: www.genelec.com

E-mail: genelec@genelec.com

AMPLIFIER

SECTION

 

1094A

1092A

Short term amplifier output

 

 

 

power :

400 W (8 Ohm) 180 W (4 Ohm)

(Long term output power is limited

 

 

by driver unit protection circuitry.)

 

 

 

Amplifier system distortion

 

 

 

at nominal output:

 

 

 

THD

 

< 0.08%

< 0.08%

SMPTE-IM

< 0.08%

< 0.08%

CCIF-IM

 

< 0.08%

< 0.08%

DIM 100

 

< 0.08%

< 0.08%

Signal to Noise ratio,

 

 

 

referred to full output:

 

> 100 dB

> 100 dB

Mains voltage:

 

100/200 or 115/230V

Voltage operating range:

 

± 10%

 

Power consumption (average):

 

 

 

Idle

 

60 VA

50 VA

Full output

650 VA

300 VA

INPUT

 

 

 

SECTION

 

Both Models

 

 

 

 

Input connectors: XLR female.

 

pin 1: gnd

 

 

 

pin 2: +

 

 

 

pin 3: -

 

Input impedance:

 

10 kOhm balanced

 

Input level for 100 dB SPL

 

 

 

output @ 1m:

 

variable from +6 to - 6 dBu

OUTPUT

 

 

 

SECTION

 

Both Models

 

 

 

 

Output connectors: XLR male.

 

pin 1: gnd

 

 

 

pin 2: +

 

 

 

pin 3: -

 

Output impedance:

 

100 Ohm balanced,

 

 

 

active floating

 

Gain:

 

0 dB

 

Genelec Document DR920021 (1092-0106-3)

COPYRIGHT GENELEC OY 1998 All data subject to change without prior notice

Page 8
Image 8