‹2.11.2 TRANSFER SWITCH

If this generator is used to supply power to any elec- trical system normally powered by an electric utility, the National Electrical Code requires that a transfer switch be installed. The transfer switch prevents elec- trical backfeed between two different electrical sys- tems. (For additional information, see the applicable transfer switch manual for this unit.) The transfer switch, as well as the generator and other standby components, must be properly located and mounted in strict compliance with applicable codes, standards and regulations.

‹2.11.3 FUEL SYSTEM

Make sure the fuel supply system to the generator (a) delivers the correct fuel at the correct pressure and

(b)is properly purged and leak tested according to code. No fuel leakage is permitted. See “Specifications” (Section 1.10) for more information.

‹2.11.4 GENERATOR SET LUBRICATION

Check the engine crankcase oil level before operating and add oil to the proper level – the dipstick “FULL” mark. Never operate the engine with the oil level below the dipstick “ADD” mark. See “Specifications” (Section 1.10) and “Engine Oil Recommendations” (Section 1.14).

NOTE:

This engine is shipped from the manufacturer with 15W-40 oil. This oil should be changed after 30 hours of operation.

‹2.11.5 ENGINE COOLANT

Have the engine cooling system properly filled with the recommended coolant mixture. Check the system for leaks and other problems. See “Specifications” (Section 1.10) and “Coolant” (Section 1.15).

3.1USING A STANDARD “GTS”

TRANSFER SWITCH

When required, the pre-packaged standby generator can be installed with a standard Generac “GTS” type engineered automatic transfer switch.

When a GTS type transfer switch is used, it controls automatic operation and automatic transfer as fol- lows:

Solid state circuits in the transfer switch monitor utility power source voltage.

When utility source voltage drops below a pre-set level, transfer switch action closes the circuit. The engine then cranks and starts as controlled by the pre-packaged generator’s Control Module circuit board.

After the engine starts and when the generator AC output voltage and frequency have reached a pre-set value, transfer switch circuits signal the transfer switch main contacts to actuate to the “STANDBY” power source side. Generator AC out- put then powers load circuits.

When the utility power source voltage is restored above a pre-set level, transfer switch solid state circuits signal the switch main contacts to move back to their utility power source side.

Following re-transfer back to the utility power source side, transfer switch circuit board action opens the circuit. Engine then shuts down.

NOTE:

If the generator is installed in conjunction with a standard GTS type transfer switch, refer to the applicable transfer switch manual for exact oper- ating parameters and timing sequences.

3.2CONTROL CONSOLE

COMPONENTS

The components of a liquid-cooled generator control console (Figure 3.1) are as follows:

‹2.11.6 BELT TENSION

Check the engine fan belt tension and condition prior to placing the unit into service and at recommended intervals. Belt tension is correct when a force of approximately 22 pounds (10 kg), applied midway between pulleys, deflects the belt about 3/8- to 5/8- inch (10 to 16 mm).

‹2.11.7 ELECTRICAL SYSTEM

Make sure the generator is properly connected to an approved earth ground and/or ground rod.

Make sure the generator battery is fully charged, prop- erly installed and interconnected, and ready for use.

Check to ensure that there are no loose electrical con- nections. Restrain any loose wires to keep them clear of any moving generator set components.

12 Generac® Power Systems, Inc.

Figure 3.1 - Liquid-Cooled Generator Panel

 

FUSE

FAULT

HOUR METER

15-A

INDICATOR

 

AGC

 

AUTO

 

 

 

 

SET

OFF

 

EXERCISE

 

TIME

 

 

 

 

ON

MANUAL

 

 

Page 14
Image 14
Generac 0047210, 0047220, 0047230, 0047240, 0047250, 0047251, 0047252, 0047253, 0047260 Control Console Components

0047210, 0047220, 0047230, 0047240, 0047250, 0047251, 0047252, 0047253, 0047260 specifications

Generac is renowned for its innovation in the power generation industry, and their range of generators—including models 0047210, 0047220, 0047230, 0047240, 0047250, 0047251, 0047252, 0047253, and 0047260—showcase advanced technologies and functionality that meet diverse power needs.

One of the standout features of these models is the use of Generac’s G-Force Engine, specifically designed for reliability and longevity. This engine is notorious for its durability, capable of handling demanding workloads and proving to be more efficient than typical engines found in similar generators. It provides quick start times, lower emissions, and is built to withstand extended operational cycles.

Another notable technology in these models is the Quiet-Test™ mode, which enables the generator to run at a lower RPM while it performs an exercise routine. This feature not only reduces noise during operation but also conserves fuel, making it an eco-friendly option that doesn’t compromise on performance.

The generators are equipped with advanced monitoring and control features, including the Mobile Link™ application compatibility. This allows users to monitor the status of their generator remotely via a smartphone or tablet, offering peace of mind and real-time access to the generator's operational functioning. This connectivity also enables the user to receive alerts and notifications about maintenance needs or when the generator is in need of attention.

In terms of design, these models boast a robust steel enclosure that offers superior protection against the elements, thereby enhancing durability and ensuring efficient operation regardless of weather conditions. The enclosures also come with a weather-resistant finish, making them suitable for outdoor installation.

Moreover, the generators feature a well-thought-out installation process with easily accessible controls and noise-reduction technology, which helps minimize disturbances for residential applications. They also offer multiple power outputs, catering to varied energy needs, from essential home appliances to larger devices.

Safety is a core consideration with Generac models, and features such as the automatic shutdown mechanism prevent overheating, ensuring operational safety during use. Coupled with an efficient fuel consumption rate, these generators stand out as impeccable solutions for power backup in homes and businesses alike.

The series exemplifies Generac’s commitment to excellence in power solutions, integrating user-friendly technology, efficient performance, and top-tier safety into compact, durable designs. Users can rely on models 0047210 to 0047260 for dependable power generation tailored to their specific needs.