Stopping the Engine

Unplug all electrical loads from generator panel receptacles.Never start or stop engine with electrical devices plugged in and turned on.

• Put the idle control switch in the "Off" position.

Let engine run at no-load for 30 seconds to stabilize the internal temperatures of engine and generator.

Move run/stop switch to "Stop."

Close the fuel shut-off valve.

Operating Automatic Idle Control

This switch is designed to greatly improve fuel economy. When this switch is turned ON, the engine will only

run at its normal high governed engine speed when an electrical load is connected.When an electrical load is

removed, the enginewill run at a reduced speed. With the switch off, the engine will run at the normal high engine speed. Always have the switch off when starting and

stopping the engine.

To recharge 12 Volt batteries, proceed as follows:

Check fluid level in atl battery cells. If necessary,add ONLY distilled water to cover separators in battery cells. Do Not use tap water.

If the battery isequipped with vent caps,make sure they are installed and are tight.

If necessary,clean battery terminals.

Connect battery charge cable connector plug to panel receptacle identified by the words "12 VOLTS D.C"

Connect battery charge cable clamp with red handle to the positive (+) battery terminal (Figure 6).

12 VOLT D.C.

RECEPTACLE

Charging a Battery

_ ARNING! Storage batteries give off explosive hydrogen gas while recharging.An explosive mixture

will remain around the battery for a long time after it has been charged.The slightest spark can ignite the hydrogen and causean explosion, resulting in blindness or other serious injury.

_ WARNING!flame, sparks or DoanyNototherpermitsourcesmoking,openof heat around a battery.Wear protective goggles,rubber apron and rubber gloves when working around a battery.

Battery electrolyte fluid isan extremely caustic sulfuric acid solution that can cause severe burns. If

spill occurs flush area with clear water immediately.

Your generator hasthe capability of recharging a discharged 12Volt automotive or utility style storage battery. Do Not use the unit to charge any 6Volt batteries. Do Not use the unit to crank an engine havinga discharged battery.

÷

POSNEG

12VOLTBA'I-rERY

Connect battery chargecable clamp with black handle to the negative (-) battery terminal (Figure 6).

Start engine. Let the engine run while battery recharges.

When battery has charged,shut down engine

NOTE: Use an automotive hydrometer to test battery state of charge and condition. Follow the hydrometer manufacturer'sinstructionscarefully. Generally,a battery is considered to be at 100%state of charge when specific gravity of itsfluid (as measured by hydrometer) is 1.260or higher.

/

7

Page 7
Image 7
Generac 09779-2 owner manual Stopping the Engine, Operating Automatic Idle Control, Volt D.C

09779-2 specifications

The Generac 09779-2 is a powerful and reliable portable generator designed to meet the increasing demand for backup power solutions, especially during emergencies or power outages. It stands out in the market for its impressive features, advanced technologies, and user-friendly characteristics that cater to both residential and light commercial needs.

One of the main features of the Generac 09779-2 is its robust engine, which is engineered for durability and efficiency. This generator is equipped with a Generac 2.4-gallon fuel tank, enabling it to provide significant run-time capabilities. With the ability to deliver up to 7,500 watts of starting power and 6,000 watts of running power, it can easily handle essential appliances, power tools, and even larger equipment.

The unique True Power Technology is a pivotal characteristic of the Generac 09779-2. It ensures clean and stable power, making this generator safe for sensitive electronics, such as computers and medical equipment. This technology helps to provide a smooth sine wave output, which is crucial for the optimal functioning of modern devices that require consistent power supply.

Another highlight is its user-friendly interface. The generator features an easy-to-read control panel with user-friendly gauges that display vital statistics such as fuel level, wattage output, and runtime hours. This accessibility enables users to monitor performance effortlessly and ensures that they can manage their power needs efficiently.

The Generac 09779-2 is also designed with safety and convenience in mind. It includes features such as low oil shutdown, which protects the engine from damage by automatically turning off the generator when oil levels are low. Additionally, the unit is equipped with a folding handle, making it portable and easy to transport for outdoor events or job sites.

The generator operates quietly, which is a significant advantage for residential use, as it reduces noise pollution and disturbance for neighbors. With its heavy-duty construction and reliable performance, the Generac 09779-2 is ideal for homeowners seeking peace of mind during power outages or those who require portable power solutions for recreation or work.

In summary, the Generac 09779-2 blends powerful performance, advanced technologies, and user-centric features, making it an excellent choice for anyone in search of a dependable portable generator. It exemplifies Generac's commitment to quality and innovation, delivering both reliability and efficiency.