5500 Watt Heavy Duty Generator

3.Slide the axle through the holes in the brackets provided on the generator cradle.

Add Gasoline

4.Slide a wheel and flat washer on one end of the axle. Make sure the air inflation valve is outward. Insert the retaining pin.

5.Slide the axle through until wheel is tight against bracket.

6.Slide the other wheel and flat washer on the other end of the axle. Make sure the air inflation valve is outward. Insert the retaining pin using the needle-nose plier.

Remove the wooden blocks.

7.Attach the vibration mounts to the support leg with 30mm capscrews, washers and lock nuts.

8.To aid support leg assembly, rest generator on cradle, engine end down. Remove the existing hardware from the left unit vibration mount with 13mm wrench. Use the same hardware to attach the support leg.

9.Attach the other side of the support leg with a 20mm cap screw and lock nut. Rest generator on wheels and support leg.

10.Center the handle bracket on generator frame at support leg end of cradle, as shown.

11.Attach handle bracket with two M8 x 45mm cap screws and two locking hex nuts.

12.Check each fastener to ensure it is secure and the tires are inflated between 15-40 PSI.

BEFORE STARTING THE

ENGINE

Add Oil

CAUTION! Any attempt to crank or start the engine before it has been properly filled with the recommended oil may result in an engine failure.

To fill your engine with oil:

Place generator on a level surface.

Follow the oil grade recommendations and oil fill instructions given in the engine owner’s manual.

NOTE: The generator’s revolving field rides on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.

WARNING! Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot.Allow unit to cool for two minutes before refueling. Do Not light a cigarette or smoke when filling the fuel tank.

WARNING! Do Not overfill the fuel tank. Always allow room for fuel expansion.

Use regular UNLEADED gasoline with the generator engine. Do Not use premium gasoline. Do Not mix oil with gasoline.

Clean area around fuel fill cap, remove cap.

Slowly add unleaded regular gasoline to fuel tank. Be careful not to overfill. Allow about 1.5" of tank space for fuel expansion (Figure 2).

Figure 2 — Typical Fuel Expansion Space

Airspace

Tank

 

1.5”

Fuel

 

• Install fuel cap and wipe up any spilled gasoline.

IMPORTANT: It is important to prevent gum deposits from forming in essential fuel system parts, such as the carburetor, fuel filter, fuel hose or tank during storage. Also, experience indicates that alcohol–blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic fuel can damage the fuel system of an engine while in storage.

To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer. See “Storage” on page 11. Never use engine or carburetor cleaner products in the fuel tank or permanent damage may occur.

5

Page 5
Image 5
Generac 1654-0 owner manual Before Starting Engine, Add Gasoline, Add Oil, To fill your engine with oil

1654-0 specifications

The Generac 1654-0 is a high-performance portable generator designed for reliable power supply during outages, outdoor activities, or construction projects. One of its standout features is its robust engine, which provides ample wattage to run essential appliances and tools. With a starting wattage of around 16,000 watts and continual power of approximately 15,000 watts, the Generac 1654-0 can effortlessly support larger devices, including refrigerators, air conditioners, and power tools.

A defining characteristic of the 1654-0 is its advanced Generac OHV engine, which is built for durability and efficiency. This horizontal shaft engine features a durable design that offers consistent performance over time, ensuring you won't be left without power when you need it most. The generator is also designed with a heavy-duty steel frame, providing added stability and protection.

The Generac 1654-0 is equipped with a large-capacity fuel tank that can hold around 10 gallons of gasoline. This generous fuel capacity allows for extended run times, making it perfect for long events or power outages. Additionally, a fuel gauge is incorporated, allowing users to monitor fuel levels easily.

One of the key technologies used in the 1654-0 is its True Power Technology, which provides clean and stable energy. This technology is crucial for sensitive electronic devices as it minimizes harmonic distortion to less than 5%, protecting your equipment from potential damage.

Convenience features are also abundant in the Generac 1654-0. The generator includes multiple outlets, offering a variety of connection options for different devices. There are also circuit breakers for added protection, ensuring safe operation.

The unit is designed with user-friendly controls and an easy-to-read LCD display that shows runtime hours, wattage used, and maintenance alerts. These features make it simple to manage and monitor the generator.

Another notable aspect is the generator’s portability. With sturdy wheels and a fold-down handle, it can be easily maneuvered to wherever you need power. Coupled with a lightweight design, the Generac 1654-0 addresses both performance and portability, making it an excellent choice for a variety of power needs. Whether for emergency backup or recreational use, the Generac 1654-0 stands out as a reliable and efficient solution.