Generac Mega 2500 Extended Life Generator

STORAGE INSTRUCTIONS

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.

GENERATOR

Clean the generator as outlined in “To Clean the Gen- erator.”

Check that cooling air slots and openings on genera- tor are open and unobstructed.

DANGER: If you use a storage cover, do not place over a hot generator. Let the unit cool for a sufficient time before placing a cover on the unit. Placing a cover on the unit before generator is sufficiently cool could could start the cover on fire.

OTHER STORAGE TIPS

Do not store gasoline from one season to another.

Replace your gasoline can if it starts to rust. Rust and/or dirt in a gasoline can cause problems when you use that fuel with this unit.

Store in clean and dry area.

SPECIFICATIONS

 

GENERATOR

 

Rated Maximum Continuous

 

AC Power Output ...................................

2000 Watts (2.0 kW)

Rated Voltage.........................................

120

Rated Maximum Current at 120 Volts ....

15 AC amperes

Phase.....................................................

1

Rated AC Frequency..............................

60 Hertz

Number of Rotor Poles...........................

1

Driven Speed of Rotor............................

3600 rpm

ENGINE

See Engine Owner’s Manual for instructions on how to properly store the engine.

E x t e n d e d L i f e G e n e r a t o r