Generac MPSG350 manual Modular Power System MPS, Features

Models: MPSG350

1 4
Download 4 pages 7.69 Kb
Page 1
Image 1

Modular Power System (MPS)

MPSG350 350 kW

Standby Power Rating

Prime Power Rating

350 KW 60 Hz

280 KW 60 Hz

 

 

 

 

 

Powered with Generac’s 13.3 Natural Gas Engine

 

 

 

 

 

 

Diesel Generator

GEN

Circuit

Breaker

Contactor

Diesel Generator

GEN

Circuit

Breaker

Contactor

Diesel Generator

Diesel Generator

GEN

GEN

Circuit

Circuit

Breaker

Breaker

Contactor

Contactor

Control Wires

PMSC

Controller

Cabinet

Distribution

Cab

UTILITY

Transfer Sw

W/ Integral

Control

Distribution

Cab

UTILITY

UTILITY

ATS

 

ATS

 

Distribution Cab

Power Manager Integrated Controller Layout

Power Manager System Controller Layout

FEATURES

nThe Generac Modular Paralleling system utilizes multiple small generators in a side by side parallel arrangement to achieve a larger combined power output.

nThe proven 13.3 liter Generac generators can be combined up to 10 units to provide from 300 kW to 1 megawatts of reliable power.

nParalleling System Features. The paralleling function is controlled by Generac’s field proven Power Manager Control utilizing contractor switching technology resulting in cost effective reliable paralleling. The MPS control system provides automatic synchronization, adjustable load sharing between generators, reverse power protection and load shedding contacts.

nThe optional cable interconnect cabinet is furnished with bus bar and lugs to allow easy cabling between the multiple gensets. Recommended for 3 or more gensets.

nThe Generac “Power Manger Generator controller” provides complete engine monitoring and control along

with alarm function and communication ability via a RS232 with a modem link to Generac’s Genlink software or Modbus control. A RS485 link is also available.

nFlexibility. The Modular Power systems flexibility allows for a wide variety of configurations, including single or multiple automatic transfer switch arrangements roof application where better weight distribution is required and areas with specific height or depth limitations. Since MPS gensets need not be located together, space can be utilized wherever it is available. Smaller units are also easier to transport and place on the jobsite.

nRedundancy. N+1 means greater reliability with MPS. Backup power during scheduled maintenance. Simplified service which reduces maintenance costs.

nSingle source service response from Generac’s dealer network provides parts and service support for the entire unit. You are never on your own when you own a Generac Power System

®