Standby Generator Sets

Maintenance

MISCELLANEOUS MAINTENANCE

‹CLEANING THE GENERATOR

Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen- erator windings have an adverse effect on insulation resistance.

Periodically clean generator exterior surfaces. A soft brush may be used to loosen caked on dirt. Use a vacuum system or dry, low pressure air to remove any accumulations of dirt. The generator is housed inside an all-weather enclosure, clean the enclosure with a soft, damp cloth or sponge and water.

Once each year have the generator cleaned and inspected by an Authorized Service Dealer. That dealer will use dry, low pressure air to clean internal windings. Parts inside the control console should be cleaned and inspected at this time as well.

Finally, have the insulation resistance of stator and rotor windings checked. If insulation resistances are excessively low, the generator may require drying.

‹BATTERY

2.Check the battery fluid level of unsealed batteries and, if necessary, fill with DISTILLED WATER ONLY. DO NOT USE TAP WATER IN BATTERIES.

3.Have the state of charge and condition checked. This should be done with an automotive-type bat- tery hydrometer.

DANGER

Storage batteries give off explosive hydrogen gas. This gas can form an explosive mixture around the battery for several hours after charg- ing. The slightest spark can ignite the gas and cause an explosion. Such an explosion can shat- ter the battery and cause blindness or other injury. Any area that houses a storage battery must be properly ventilated. Do not allow smok- ing, open flame, sparks or any spark producing tools or equipment near the battery.

Battery electrolyte fluid is an extremely corro- sive sulfuric acid solution that can cause severe burns. Do not permit fluid to contact eyes, skin, clothing, painted surfaces, etc. Wear protective goggles, protective clothing and gloves when handling a battery. If fluid is spilled, flush the affected area immediately with clear water.

All lead-acid storage batteries discharge when not in use. Refer to specific instructions and warnings that accompany the battery. If such information is not available, observe the following precautions when handling a battery:

DO NOT use jumper cables and a booster battery to crank or start the generator engine.

DO NOT recharge a weak battery while it is installed in the generator. Remove battery from generator and recharge in a well-ventilated area, away from fuel vapors, sparks, heat or flames.

Battery electrolyte fluid is an extremely caustic sulfuric solution that can cause severe burns. DO NOT permit fluid to contact eyes, skin, clothing, painted surfaces, wiring insulation, etc. If any bat- tery fluid is spilled, flush the affected area with clear water immediately.

Always wear safety glasses, rubber apron and gloves when handling a battery.

Batteries give off explosive hydrogen gas while charging. The gas can form an explosive mixture around the battery for several hours after charging. Any spark, heat or flames can ignite the gas and cause an explosion which can shatter the battery, causing blindness or other serious injury.

‹BATTERY MAINTENANCE

The battery should be inspected per Section 4.7, Scheduled Maintenance. The following procedure should be followed for inspection:

1. Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary.

12/05 B .Rev Maint006

Do not use any jumper cables or booster battery to crank and start the generator engine. If the battery has completely discharged, remove it from the generator for recharging.

Be sure the AUTO/OFF/MANUAL switch is set to the OFF position, before connecting the battery cables. If the switch is set to AUTO or MANUAL, the generator can crank and start as soon as the battery cables are connected.

Be sure the 120VAC power supply to the battery is turned OFF, or sparking may occur at the bat- tery posts as the cables are attached and cause an explosion.

‹BATTERY REPLACEMENT

When replacing batteries, use the same number and the type of battery that follows:

 

BCI Group No.

CCA

 

 

26

525 @ 0 deg. F

 

 

 

 

 

NOTE:

The BCI number should be located directly on the battery.

‹PERIODIC REPLACEMENT PARTS

Part Name

Part Number

Oil Filter

# 0A4531A244

Radiator Cap

# 046627

Air Cleaner

# 059402

Spark Plug

# 0A45310275

10-4

Page 19
Image 19
Generac QT owner manual Miscellaneous Maintenance

QT specifications

Generac QT is a line of advanced, high-quality standby generators designed for residential and commercial use. These generators are engineered to provide reliable backup power in the event of a utility outage, ensuring that homes and businesses remain operational during unforeseen circumstances.

One of the main features of the Generac QT series is its powerful engine, designed to deliver robust performance. The generators typically come equipped with Generac’s G-Force engine, renowned for its durability and long life. This engine is built to run at a lower RPM compared to competitors, which not only reduces noise but also enhances the overall lifespan of the generator.

The QT series also boasts a self-test mode, allowing users to conduct routine checks to ensure the generator remains in optimal condition. This feature minimizes the risk of unexpected failures and ensures that the unit is always ready for action when needed. Additionally, the generators are equipped with a power management system that intelligently balances the load, ensuring that essential systems receive power during an outage.

Another standout characteristic of the Generac QT series is its Quiet-Test technology. This innovative feature allows the generator to run at a lower decibel level during routine testing, making it less intrusive in residential areas while still ensuring functionality. This aspect highlights Generac's commitment to creating products that are not only efficient but also considerate of the surrounding environment.

The Generac QT generators are also equipped with an advanced digital controller that provides real-time monitoring and diagnostics, making it easier for users to track performance and maintenance needs. This allows for prompt action in case any issues arise, further ensuring the reliability of the power supply.

User convenience is a priority for Generac, and the QT series reflects this with its easy-to-understand control panel. The intuitive design makes it simple for users to monitor generator status, adjust settings, and understand power usage. Furthermore, the generators can be integrated with home automation systems, providing an added layer of convenience and control.

Overall, the Generac QT series stands out for its powerful engine, advanced technologies, and user-friendly features. It is an excellent option for those looking to invest in a dependable standby generator that meets modern energy needs while maintaining efficiency and operating quietly. With its focus on quality and innovation, Generac continues to be a leader in the power generation industry.