Standby Generator Sets Engine Protective Devices

ENGINE PROTECTIVE DEVICES

The standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant tempera- ture, oil pressure or rpm. For that reason, the engine has several devices designed to protect it against potentially damaging conditions by automatically shutting down the unit when the oil pressure is too low, the coolant temperature is too high, the coolant level is too low, or the engine is running too fast.

NOTE:

Engine protective switches and sensors are men- tioned here for the reader’s convenience. Also refer to the applicable control panel manual for additional automatic engine shutdown informa- tion.

‹HIGH COOLANT TEMPERATURE SWITCH

This switches contacts close if the temperature should exceed approximately 140° C (284° F), initiating an engine shutdown. The generator will automatically restart and the LED will reset once the temperature has returned to a safe operating level.

‹LOW COOLANT LEVEL SENSOR

Should the engine coolant level drop below the level of the high coolant temperature switch, it is possible for the engine to overheat without automatic shut- down. To prevent such overheating, the engine has a low coolant level sensor. If the level of engine coolant drops below the level of the low coolant level sensor, the engine automatically shuts down.

‹OVERCRANK SHUTDOWN

After a prespecified duration of cranking, this func- tion ends the cranking if the engine has failed to start. The overcrank LED will turn ON. Turn OFF the AUTO/OFF/MANUAL switch, then turn switch back to AUTO to reset the generator control board.

NOTE:

If the fault is not corrected, the overcrank feature will continue to activate.

Approximate Crank Cycle Times

15 seconds ON

7 seconds OFF

7 seconds ON

7 seconds OFF

Repeat for 45 seconds Approximately 90 seconds total.

‹OVERSPEED SHUTDOWN

A speed circuit controls engine cranking, start-up, operation and shutdown. Engine speed signals are delivered to the circuit board whenever the unit is running. Should the engine overspeed above a safe, preset value, the circuit board initiates an automatic engine shutdown. Contact the nearest Authorized Dealer if this failure occurs.

‹RPM SENSOR LOSS SHUTDOWN

If the speed signal to the control panel is lost, engine shutdown will occur.

‹LOW OIL PRESSURE SWITCH

This switch has normally closed contacts that are held open by engine oil pressure during cranking and operating. Should oil pressure drop below the 8 psi range, switch contacts close, and the engine shuts down. The unit should not be restarted until oil is added, and the AUTO/OFF/MANUAL switch must be turned to OFF and then back to AUTO.

‹DC FUSE

This fuse is located inside of the control panel. It protects the panel wiring and components from damaging overload. Always remove this fuse before commencing work on the generator. The unit will not start or crank if the fuse is blown. Replace the fuse with one of the same size, type, and rating. (See the exploded views and parts lists at the end of this manual for replacement part number.)

4-1

08/05

0 .Rev EngProt001

Page 8
Image 8
Generac QT owner manual Engine Protective Devices

QT specifications

Generac QT is a line of advanced, high-quality standby generators designed for residential and commercial use. These generators are engineered to provide reliable backup power in the event of a utility outage, ensuring that homes and businesses remain operational during unforeseen circumstances.

One of the main features of the Generac QT series is its powerful engine, designed to deliver robust performance. The generators typically come equipped with Generac’s G-Force engine, renowned for its durability and long life. This engine is built to run at a lower RPM compared to competitors, which not only reduces noise but also enhances the overall lifespan of the generator.

The QT series also boasts a self-test mode, allowing users to conduct routine checks to ensure the generator remains in optimal condition. This feature minimizes the risk of unexpected failures and ensures that the unit is always ready for action when needed. Additionally, the generators are equipped with a power management system that intelligently balances the load, ensuring that essential systems receive power during an outage.

Another standout characteristic of the Generac QT series is its Quiet-Test technology. This innovative feature allows the generator to run at a lower decibel level during routine testing, making it less intrusive in residential areas while still ensuring functionality. This aspect highlights Generac's commitment to creating products that are not only efficient but also considerate of the surrounding environment.

The Generac QT generators are also equipped with an advanced digital controller that provides real-time monitoring and diagnostics, making it easier for users to track performance and maintenance needs. This allows for prompt action in case any issues arise, further ensuring the reliability of the power supply.

User convenience is a priority for Generac, and the QT series reflects this with its easy-to-understand control panel. The intuitive design makes it simple for users to monitor generator status, adjust settings, and understand power usage. Furthermore, the generators can be integrated with home automation systems, providing an added layer of convenience and control.

Overall, the Generac QT series stands out for its powerful engine, advanced technologies, and user-friendly features. It is an excellent option for those looking to invest in a dependable standby generator that meets modern energy needs while maintaining efficiency and operating quietly. With its focus on quality and innovation, Generac continues to be a leader in the power generation industry.