5)

 

 

UL CIRCUIT BREAKER (QJ-2P)

A

0F8137

1

COVER QJ 2P FRM CB

B

065469

1

DECAL, DANGER HIGH VOLTAGE

C

0E7994

-

CB 0225A 240V 2P S QJ22

D

0F8136

1

COVER QJ 2P CB DISH

E

036261

4

RIVET POP .125 X .275 SS

F

022473

2

WASHER FLAT 1/4-M6 ZINC

G

022097

2

WASHER LOCK M6-1/4

H

022127

2

NUT HEX 1/4-20 STEEL

J

0F8139

1

INSUL CB 2P QJ

K

0C2454

7

SCREW THF M6-1 X 16 N WA Z/JS

L

022237

2

WASHER LOCK 3/8

M

048527

2

SCREW SHC 3/8-16 X 3/4 G8.8 NZ

N

029289

1

TAPE ELEC 1/2 FOAM (AS REQ’D)

P

022770

2

SCREW RHM 1/4-20 X 3

Q

0F1733

1

DECAL CUSTOMER CONNECT INSIDE

6)

 

 

UL CIRCUIT BREAKER (225AF)

A

0F4185

1

COVER CB C2-C4 225AF

B

065469

1

DECAL DANGER HIGH VOLTAGE

C

0F4165$

REF

CIRCUIT BREAKERS 200A FRAME

D

0F4186

1

COVER CB DISH 225AF

E

036261

4

RIVET POP .125 X .275 SS

F

053640

4

SCREW RHM #8-32 X 3-1/4

G

038150

4

WASHER FLAT #8 ZINC

H

022264

4

WASHER LOCK #8-M4

J

022471

4

NUT HEX #8-32 STEEL

K

029289

2

TAPE ELEC 1/2 FOAM

L

0F1733

1

DECAL CUSTOMER CONNECT INSIDE

M

022129

9

WASHER LOCK M8-5/16

N

0F8432

1

INSULATOR CB 225AF

P

0C2454

7

SCREW THF M6-1 X 16 N WA Z/JS

R

0F8451

3

LUG SLDLSS 300 MCM-6 AL/CU

S

049897

9

SCREW SHC M8-1.25 X 20 G8

T

022145

6

WASHER FLAT 5/16-M8 ZINC

U

045771

3

NUT HEX M8-1.25 G8 CLEAR ZINC

V

0F8843

3

BUS BAR 200A LUG ADAPTOR

(1) W

W/CB

2

TERMINAL COVER CB

7)

 

 

UL CIRCUIT BREAKER (400AF)

A

0F4187

1

COVER CB C2-C4 400AF

B

065469

1

DECAL DANGER HIGH VOLTAGE

C

0F4166$

REF

CIRCUIT BREAKERS 400A FRAME

D

0F1733

1

DECAL CUSTOMER CONNECT INSIDE

E

042419

4

SCREW RHM 10-32 X 4

F

023897

4

WASHER FLAT #10 ZINC

G

022152

4

WASHER LOCK #10

H

022158

4

NUT HEX #10-32 STEEL

J

0C2454

7

SCREW THF M6-1 X 16 N WA Z/JS

K

029289

1

TAPE ELEC 1/2 FOAM

(2) L

052647

2/3

SCREW SHC M10-1.5 X 25 G12.9

(2) M

046526

2/3

WASHER LOCK M10

N

W/CB

3

BUS BAR CB ADAPTER 225-400 A

P

0A7822

3

LUG SLDLSS 600/250-1/0 X 1/4-28

(1) S

W/CB

2

TERM COVER CB

T

023334

6

SCREW HHC 1/4-28 X 1/2 G5

U

022097

6

WASHER LOCK M6-1/4

V

022473

6

WASHER FLAT 1/4-M6 ZINC

(2) W

W/CB

2/3

SCREW SHC M10-1.5 X 25 G12.9

(2) X

W/CB

2/3

WASHER LOCK M10

8)

 

 

NEUTRAL BLOCK 390 / 200-400A

A

0D5466

2

BUS BAR NEUTRAL BLOCK 390

B

039287

1

SCREW HHC M8-1.25 X 45 G8.8 FT

C

022145

1

WASHER FLAT 5/16-M8 ZINC

D

022129

1

WASHER LOCK M8-5/16

E

045771

1

NUT HEX M8-1.25 G8 YEL CHR

F

045335

2

SCREW HHC 1/4-28 X 3/4 G5

G

083896

2

WASHER LOCK 1/4-M6 SS

H

0A7822

1

LUG SLDLSS 600/250-1/0 X 1/4-28

(1)HARDWARE FOR MTG. CB TERMINAL COVERS IS SUPPLIED WITH CIRCUIT BREAKERS.

(2)2/3 QTY. 2 POLE & 3 POLE CB.

Page 29
Image 29
Generac Power Systems 005261-1, 005262-1 owner manual UL Circuit Breaker QJ-2P

005261-1, 005262-1 specifications

Generac Power Systems, a leader in backup power solutions, offers a range of generators designed to meet different power needs. Among their notable products are the Generac models 005261-1 and 005262-1, which are both excellent options for residential and commercial applications. These generators are specifically designed to provide reliable power during outages, ensuring that homes and businesses remain operational when it matters most.

One of the standout features of the Generac 005261-1 and 005262-1 models is their automatic transfer switch technology. This feature allows the generators to detect power outages automatically and switch on within seconds, providing uninterrupted power. The systems are designed for ease of use, with a user-friendly control panel that displays critical information about the generator’s status and maintenance requirements.

Both models are powered by Generac's innovative engine technology, which ensures superior performance and fuel efficiency. The engines are engineered to run quietly while delivering ample power output. The 005261-1 typically offers up to 22 kW of backup power, while the 005262-1 goes up to 26 kW, making them suitable for larger homes or essential commercial applications.

In terms of construction, the Generac models feature durable weather-resistant enclosures, ensuring they can withstand harsh environmental conditions. Their compact design makes installation straightforward, with options for both concrete pads and low-profile installations. Furthermore, both generators are equipped with a state-of-the-art digital controller that allows users to monitor the system remotely.

Another important characteristic is the Generac Power Zone Mobile Link, which allows users to monitor their generator’s status via a smartphone app. This feature provides peace of mind, as users can receive alerts regarding power outages, routine maintenance, and operational status in real time, even when they are not home.

The maintenance of these generators is simplified by their built-in features, including an integrated maintenance reminder system that alerts users when service is due. This proactive approach aids in extending the life of the generator and optimizing performance over time.

In summary, the Generac Power Systems models 005261-1 and 005262-1 offer a blend of reliability, efficiency, and advanced technology. With automatic transfer switches, robust engine design, and smart monitoring capabilities, these generators stand out in the market as excellent choices for backup power needs. Whether for residential use or light commercial applications, users can trust in Generac’s commitment to delivering dependable power solutions.