Important Safety Instructions

Read the following information carefully before attempting to install, operate or service this equip-

! ment. Also read the instructions and information on tags, decals, and labels that may be affixed to ! the transfer switch. Replace any decal or label that is no longer legible.

DANGER! Connection of a generator to an electrical system normally supplied by an electric utility

! shall be by means of suitable transfer equipment so as to isolate the electric system from utility dis- ! tribution system when the generator is operating (Article 701 Legally Required Standby Systems or Article 702 Optional Standby Systems, as applicable). Failure to isolate electric system by these

means may result in damage to generator and may result in injury or death to utility workers due to backfeed of electrical energy.

Generac cannot possibly anticipate every possible cir cumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work method or operating tech- nique Generac does not specifically recommend, you must satisfy yourself that it is safe for you and others. You also must make sure the procedure, work method or operating technique that you choose does not render the transfer switch unsafe.

Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTE blocks are used to alert you to special instruction about a particular operation that may be hazardous if performed incorrectly or care- lessly. Observe them carefully. Their definitions are as follows:

DANGER

After this heading, you can read instructions that, if not strictly complied with, will result in personal injury or property damage.

After this heading, you can read instructions that, if not strictly complied with, may result in personal injury or property damage.

After this heading, you can read instructions that, if not strictly complied with, could result in damage to equipment and/or property.

NOTE:

After this heading, you can read explanatory statements that require special emphasis.

These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compli- ance with the special instructions while performing the service are essential to preventing accidents.

Four commonly used safety symbols accompany the DANGER, WARNING and CAUTION blocks. The type of information each indicates follows:

This symbol points out important safety informa- ! tion that, if not followed, could endanger personal

safety and/or property of you and others.

This symbol points out potential explosion hazard.

This symbol points out potential fire hazard.

This symbol points out potential electrical shock hazard.

! GENERAL HAZARDS !

Any AC generator that is used for backup power if a NORMAL (utility) power source failure occurs, must be isolated from the NORMAL (utility) power source by means of an approved transfer switch. Failure to properly isolate the NORMAL and STANDBY power sources from each other may result in injury or death to electric utility workers, due to backfeed of electrical energy.

Improper or unauthorized installation, operation, service or repair of the equipment is extremely dangerous and may result in death, serious per- sonal injury, or damage to equipment and/or per- sonal property.

Extremely high and dangerous power voltages are present inside an installed transfer switch. Any contact with high voltage terminals, contacts or wires will result in extremely hazardous, and pos- sibly LETHAL, electric shock. DO NOT WORK ON THE TRANSFER SWITCH UNTIL ALL POWER VOLTAGE SUPPLIES TO THE SWITCH HAVE BEEN POSITIVELY TURNED OFF.

Competent, qualified personnel should install, operate and service this equipment. Adhere strict- ly to local, state and national electrical and build- ing codes. When using this equipment, comply with regulations the National Electrical Code (NEC), CSA Standard; C22.1 Canadian Electric Code and Occupational Safety and Health Administration (OSHA) have established.

Never handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT.

Generac® Power Systems, Inc.

Page 2
Image 2
Generac Power Systems 09229-0, 09227-0, 09230-0, 09228-0 owner manual General Hazards

09229-0, 09228-0, 09230-0, 09227-0 specifications

Generac Power Systems has established itself as a leading manufacturer in the power generation industry, and models such as the Generac Power Systems 09227-0, 09230-0, 09228-0, and 09229-0 exemplify their commitment to innovation and reliability. These models are specifically designed for residential use, providing uninterrupted power during outages and ensuring that homes remain functional and comfortable.

One of the standout features of these Generac models is their use of advanced automatic transfer switch technology. This seamless transition between utility power and generator power minimizes downtime during power outages, allowing homeowners to maintain their daily routines without interruption. The automatic transfer switches are equipped with sophisticated monitoring systems that can detect power loss and engage the generator within seconds.

Furthermore, the engines in these models are designed for optimal efficiency, often featuring a heavy-duty design that ensures longevity and reliability. This durability is complemented by Generac's G-Force engine technology, which is designed for rigorous use and is tested under extreme conditions. These engines are also built to run on natural gas or propane, providing flexibility depending on fuel availability and user preference.

In terms of noise reduction, Generac has incorporated innovative sound-dampening technology, ensuring that these generators operate quietly. This is particularly important for residential areas where noise pollution can be a concern.

The models also come equipped with user-friendly interfaces, making it easy for homeowners to monitor and control their power systems. Digital displays provide real-time information on power production and battery status, while intuitive controls allow for straightforward operation and maintenance.

Additionally, the Generac Power Systems 09227-0, 09230-0, 09228-0, and 09229-0 models feature robust safety precautions. These include automatic shutdown mechanisms that activate in the event of low oil pressure or overheating, thus protecting both the generator and the home.

With their combination of efficiency, reliability, and advanced technology, the Generac Power Systems 09227-0, 09230-0, 09228-0, and 09229-0 offer homeowners a practical solution for backup power needs. They reflect Generac's ongoing mission to provide dependable power solutions that enhance the quality of life, particularly during unpredictable weather events or public utility failures.