Generac Power Systems UL 2200 manual Application & Engineering Data

Models: UL 2200

1 4
Download 4 pages 10.94 Kb
Page 2
Image 2
APPLICATION

APPLICATION

& ENGINEERING DATA

COMMERCIAL 70 kW

GENERATOR SPECIFICATIONS

ENGINE SPECIFICATIONS

 

 

 

TYPE

Synchronous

ROTOR INSULATION

Class H

STATOR INSULATION

Class H

TOTAL HARMONIC DISTORTION

<3.5%

TELEPHONE INTERFERENCE FACTOR (TIF)

<50

ALTERNATOR OUTPUT LEADS 3 PHASE

4 wire

BEARINGS

Sealed Ball

COUPLING

Flexible Disc

LOAD CAPACITY (STANDBY RATING)

70 kW

EXCITATION SYSTEM

Direct

NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.

VOLTAGE REGULATOR

TYPE

Full Digital

SENSING

3 Phase

REGULATION

± 1/4%

FEATURES

Built into H-100 Control Panel

 

V/F Adjustable

 

Adjustable Voltage and Gain

MAKE

Generac

MODEL

V Type

CYLINDERS

10

DISPLACEMENT

6.8 Liter

BORE

3.55

STROKE

4.17

COMPRESSION RATIO

9:1

INTAKE AIR SYSTEM

Naturally Aspirated

VALVE SEATS

Hardened

LIFTER TYPE

Hydraulic

GOVERNOR SPECIFICATIONS

TYPE

Electronic

FREQUENCY REGULATION

Isochronous

STEADY STATE REGULATION

± 0.25%

All functions are factory preset

 

Individual parameter adjustments can be made via GenLink®

 

GENERATOR FEATURES

Revolving field heavy duty generator Directly connected to the engine

Operating temperature rise 120 °C above a 40 °C ambient Insulation is Class H rated at 150 °C rise

All prototype models have passed three phase short circuit testing

ENGINE LUBRICATION SYSTEM

OIL PUMP

Gear

OIL FILTER

Full flow spin-on cartridge

CRANKCASE CAPACITY

5 Quarts

CONTROL PANEL FEATURES

TWO FOUR LINE LCD DISPLAYS READ:

• Voltage (all phases)

• Current (all phases)

• Power factor

• kW

• kVAR

• Transfer switch status

• Engine speed

• Low fuel pressure

• Run hours

• Service reminders

• Fault history

• Oil pressure

• Coolant temperature

• Time and date

• Low oil pressure shutdown

• High coolant temperature shutdown

• Overvoltage

• Overspeed

• Low coolant level

• Low coolant level

• Not in auto position (flashing light)

• Exercise speed

• ATS selection

 

INTERNAL FUNCTIONS:

I2T function for alternator protection from line to neutral and line to line short circuits

Emergency stop

Programmable auto crank function

2 wire start for any transfer switch

Communicates with the Generac HTS transfer switch

Built-in 7 day exerciser

Adjustable engine speed at exerciser

RS232 port for GenLink® control

RS485 port remote communication

Canbus addressable

Governor controller and voltage regulator are built into the master control board

Temperature range -40 °C to 70 °C

ENGINE COOLING SYSTEM

TYPE

Closed

WATER PUMP

Belt driven

FAN SPEED

2030

FAN DIAMETER

22 inches

FAN MODE

Pusher

FUEL SYSTEM

FUEL TYPE

Natural gas, propane vapor

CARBURETOR

Down Draft

SECONDARY FUEL REGULATOR

Standard

FUEL SHUT OFF SOLENOID

Standard

OPERATING FUEL PRESSURE

11” - 14” H2O

ELECTRICAL SYSTEM

BATTERY CHARGE ALTERNATOR

.....................................................................12V 30

Amp

STATIC BATTERY CHARGER

12V 2

Amp

RECOMMENDED BATTERY

Group 24F, 525CCA

SYSTEM VOLTAGE

12 Volts

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).

Page 2
Image 2
Generac Power Systems UL 2200 manual Application & Engineering Data