Generac Power Systems UL 2200 manual Operating Data, COMMERCIAL 70 kW

Models: UL 2200

1 4
Download 4 pages 10.94 Kb
Page 3
Image 3
OPERATING DATA

COMMERCIAL 70 kW

COMMERCIAL SERIES

OPERATING DATA

 

 

 

COMMERCIAL 70 kW

 

KW RATING

 

 

70

 

 

 

 

 

 

ENGINE SIZE

 

 

6.8 Liter V-10

 

 

 

 

 

 

GENERATOR OUTPUT VOLTAGE/KW - 60 Hz

 

KW

AMP

CB Size

120/240V, single phase, 1.0 pf

 

70 LP / 68 NG

291.6 LP / 283.3 NG

300

120/208V, 3-phase, 0.8 pf

 

70 LP / 68 NG

243.1 LP / 236.2 NG

300

120/240V, 3-phase, 0.8 pf

 

70 LP / 68 NG

210.7 LP / 204.7 NG

250

277/480V, 3-phase, 0.8 pf

 

70 LP / 68 NG

105.3 LP / 102.4 NG

125

 

 

 

 

 

GENERATOR LOCKED ROTOR KVA

 

 

 

 

AVAILABLE @ VOLTAGE DIP OF 35%

 

 

 

 

Single phase or 208V & 240V 3-phase

 

 

145

 

480V 3-phase

 

 

160

 

 

 

 

 

 

ENGINE FUEL CONSUMPTION (Natural Gas) (Propane)

 

Natural Gas

 

Propane

 

 

(ft3/hr.)

(gal/hr.)

cu ft/hr

Exercise cycle

 

110

1.20

44.2

25% of rated load

 

260

2.85

104.9

50% of rated load

 

499

5.46

200.9

75% of rated load

 

696

7.62

280.4

100% of rated load

 

1020

11.17

411

 

 

 

 

 

ENGINE COOLING

ft3/min.

 

 

 

Air flow (inlet air including alternator and combustion air)

 

5200

 

System coolant capacity

US gal.

 

4.5

 

Heat rejection to coolant

BTU/hr.

 

287,000

 

Max. operating air temp. on radiator

°C (°F)

 

60 (150)

 

Max. ambient temperature

°C (°F)

 

50 (140)

 

 

 

 

 

 

COMBUSTION AIR REQUIREMENTS

 

 

 

 

Flow at rated power 60 Hz

cfm

 

205

 

 

 

 

 

 

SOUND EMISSIONS IN DBA

 

 

 

 

db(A) @ 23 feet in exercise mode

 

 

61

 

db(A) @ 23 feet at normal operating load

 

 

65

 

 

 

 

 

 

EXHAUST

 

 

 

 

Exhaust flow at rated output 60 Hz

cfm

 

557

 

Exhaust temp. at muffler outlet

°F

 

890

 

 

 

 

 

 

ENGINE PARAMETERS

 

 

 

 

Rated synchronous RPM

60 Hz

 

1800

 

HP at rated KW

60 Hz

 

110.7

 

 

 

 

 

 

POWER ADJUSTMENT FOR AMBIENT CONDITIONS

 

 

 

 

Temperature Deration

 

 

 

 

3% for every 10 °C above - °C

 

25

 

1.65% for every 10 °F above - °F

 

77

 

Altitude Deration

 

 

 

 

1% for every 100 m above - m

 

183

 

3% for every 1000 ft. above - ft.

 

600

 

RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc.

Page 3
Image 3
Generac Power Systems UL 2200 manual Operating Data, COMMERCIAL 70 kW