Genie 3060 Maintenance and Adjustments, Keep the path clear, Close Adjustment, Open Adjustment

Models: 3060 2060 TRUE

1 14
Download 14 pages 3.79 Kb
Page 7
Image 7

Maintenance and Adjustments

Adjustment 1: Ch Adjusting Limit Switches and Force Controls

WARNING:

A moving garage door can cause serious injury or death.

Keep the path clear.

Position the ladder to the side of the Power Head so it is clear of all moving parts of the Opener and the door..

Set the door Opener to use the minimum force needed to open the door..

ACLOSE ADJUSTMENT

On front panel of Power Head find adjusting screw marked “CLOSE” (Figure MA-1)..

Gently turn screw counterclockwise until it stops.

Very little force is required to turn adjusting screw.

Press Wall Console to close garage door.

Observe if door stops at “CLOSE” limit switch..

(Figure MA-2).. If door is fully closed—adjustment is finished.. Go to “OPEN” Adjustment.

If door stops but is not fully closed,

a.Measure distance between bottom of door and floor..

b.Move “CLOSE” Limit Switch that same distance toward door.

If door stops and/or reverses before reaching the “CLOSE” Limit Switch

a.Slightly increase CLOSE Force setting (clockwise)..

If door reverses after contacting floor, move Limit Switch toward Power Head.

If door fails to move, check Safe-T-Beam® System.. See Troubleshooting Section, pages 10-11..

Tighten Limit Switch Set Screw.. Do not over-tighten (strip) Limit Switch Set Screw..

BOPEN ADJUSTMENT

On front panel of Power Head find adjusting screw marked “OPEN” (Figure MA-1)..

Gently turn screw counterclockwise until it stops.

Very little force is required to turn adjusting screw.

Press Wall Console to close garage door.

Observe if door stops at “OPEN” limit switch.

(Figure MA-2).. If door is fully open—adjustment is finished..

If door stops but is not fully open,

a.Measure distance between bottom of door top of door opening..

b.Move “OPEN” Limit Switch that same distance toward Power Head.

If door stops before reaching the “OPEN” Limit Switch

a.Slightly increase OPEN Force setting (clockwise)..

If door fails to move, see Troubleshooting Section, pages 10-11.

Tighten Limit Switch Set Screw.. Do not over-tighten (strip) Limit Switch Set Screw..

CRun Door Opener

Cycle opener a few times to double check settings.. Repeat adjustment steps as necessary..

NOTE

Little effort is required to turn the Force Adjusting Knobs..

If the door stops moving while opening or closing, adjust the Open Force or Close Force Controls slightly clockwise (to slightly increase the force) and retry the step..

The Open Force and Close Force Controls are to be set to the minimum force necessary to ensure the door smoothly opens and

closes completely..

Ensure the Carriage Assembly is engaged and is between the two Limit Switches before operating the Opener..

FORCE

CONTROLS

 

CLOSE

CL

 

OSE

 

OPEN

OPEN

CLOSE

OPEN

Figure MA-1Making Force Adjustments

OPEN

CLOSE

Figure MA-2Making Force Adjustments

For Help, call 1-800-35-GENIE or visit www.geniecompany.com