Maintenance and Adjustments

Adjustment 1: Ch Adjusting Limit Switches and Force Controls

WARNING:

A moving garage door can cause serious injury or death.

Keep the path clear.

Position the ladder to the side of the Power Head so it is clear of all moving parts of the Opener and the door..

Set the door Opener to use the minimum force needed to open the door..

ACLOSE ADJUSTMENT

On front panel of Power Head find adjusting screw marked “CLOSE” (Figure MA-1)..

Gently turn screw counterclockwise until it stops.

Very little force is required to turn adjusting screw.

Press Wall Console to close garage door.

Observe if door stops at “CLOSE” limit switch..

(Figure MA-2).. If door is fully closed—adjustment is finished.. Go to “OPEN” Adjustment.

If door stops but is not fully closed,

a.Measure distance between bottom of door and floor..

b.Move “CLOSE” Limit Switch that same distance toward door.

If door stops and/or reverses before reaching the “CLOSE” Limit Switch

a.Slightly increase CLOSE Force setting (clockwise)..

If door reverses after contacting floor, move Limit Switch toward Power Head.

If door fails to move, check Safe-T-Beam® System.. See Troubleshooting Section, pages 10-11..

Tighten Limit Switch Set Screw.. Do not over-tighten (strip) Limit Switch Set Screw..

BOPEN ADJUSTMENT

On front panel of Power Head find adjusting screw marked “OPEN” (Figure MA-1)..

Gently turn screw counterclockwise until it stops.

Very little force is required to turn adjusting screw.

Press Wall Console to close garage door.

Observe if door stops at “OPEN” limit switch.

(Figure MA-2).. If door is fully open—adjustment is finished..

If door stops but is not fully open,

a.Measure distance between bottom of door top of door opening..

b.Move “OPEN” Limit Switch that same distance toward Power Head.

If door stops before reaching the “OPEN” Limit Switch

a.Slightly increase OPEN Force setting (clockwise)..

If door fails to move, see Troubleshooting Section, pages 10-11.

Tighten Limit Switch Set Screw.. Do not over-tighten (strip) Limit Switch Set Screw..

CRun Door Opener

Cycle opener a few times to double check settings.. Repeat adjustment steps as necessary..

NOTE

Little effort is required to turn the Force Adjusting Knobs..

If the door stops moving while opening or closing, adjust the Open Force or Close Force Controls slightly clockwise (to slightly increase the force) and retry the step..

The Open Force and Close Force Controls are to be set to the minimum force necessary to ensure the door smoothly opens and

closes completely..

Ensure the Carriage Assembly is engaged and is between the two Limit Switches before operating the Opener..

FORCE

CONTROLS

 

CLOSE

CL

 

OSE

 

OPEN

OPEN

CLOSE

OPEN

Figure MA-1Making Force Adjustments

OPEN

CLOSE

Figure MA-2Making Force Adjustments

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

7

Page 7
Image 7
Genie 3060 Maintenance and Adjustments, Keep the path clear, Little effort is required to turn the Force Adjusting Knobs

3060, 2060, TRUE specifications

The Genie TRUE, GPOWER 900, 1200, POWERLIFT 900, and 1500 are renowned products in the field of material handling, specifically designed to enhance efficiency and safety in various lifting applications.

The Genie TRUE is characterized by its innovative design that combines user-friendliness with advanced engineering. This model offers an impressive lift capacity while ensuring stability and performance. Its lightweight structure allows for easy maneuverability, making it ideal for both indoor and outdoor use. The Genie TRUE is equipped with a state-of-the-art control system that provides precise lifting, lowering, and positioning, ensuring maximum productivity for operators.

The GPOWER 900 and 1200 models stand out with their robust build and exceptional lifting capabilities. The GPOWER 900 is designed to handle loads up to 900 pounds, while the GPOWER 1200 can effortlessly lift up to 1200 pounds. Both models use advanced hydraulic systems for smooth operation, allowing for quick lifting cycles without compromising on power or safety. The ergonomic design of the GPOWER series minimizes operator fatigue, making it suitable for prolonged use in various work environments.

The POWERLIFT 900 and 1500 augment this lineup with their impressive features tailored for heavy-duty use. The POWERLIFT 900 can lift loads up to 900 pounds, making it ideal for medium-sized tasks. On the other hand, the POWERLIFT 1500 is engineered for heavier loads, boasting a capacity of 1500 pounds. Both models utilize cutting-edge overload protection technology, ensuring that safety is prioritized during use. Additionally, the POWERLIFT series features an intuitive interface that facilitates easy adjustments and control during operation.

Each of these models embodies the core values of Genie: reliability, innovation, and efficiency. They are designed to meet the varying demands of different industries, including construction, warehousing, and logistics. Their modular designs and interchangeable parts further enhance their versatility and longevity, making them a worthwhile investment for any business needing lifting solutions.

In summary, the Genie TRUE, GPOWER 900, 1200, POWERLIFT 900, and 1500 combine robust performance with safety and ease of use, making them ideal choices for any lifting task. Their reliability and advanced features are sure to meet the growing demands of modern workplaces.