Mounting Instructions for Model 6370C Parallel Power Kit

For Honda E3000i Generators Only

5

6

 

CIRCUIT BREAKER

 

 

 

 

 

STEP 6

 

 

 

 

 

Insert the set of longer Parallel Cables into “Parallel Operation” jacks

 

 

 

 

 

on second generator. Attach green/yellow ground cable to grounding

 

 

GROUND

 

 

stud on the lower right side of the second generator as well.

 

 

 

 

 

 

 

 

 

During operation, if the Parallel Power Kit is not feeding power to

 

 

 

 

 

STEP 5

your load when generators are running, it is possible that the circuit

Insert short Parallel Cables into “Parallel Operation”

breaker has been tripped. You will need to reset circuit breaker on

jacks on the first generator. Do not be concerned with

the front of the Parallel Power Kit to “ON”.

polarity when connecting to these outlets, as the

 

polarity is handled by the internal computer chip within

Be sure to shut down generators before connecting to or

the EU3000i. Then attach the first green/yellow ground

disconnecting from Parallel Power Kit.

cable to grounding stud on the lower right side of the

 

first generator using a screwdriver.

For 120 volt applications ONLY.

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: To use your paralleled generators to provide backup power to a home or other dwelling, or an RV, you will need an adapter cord to run from the

DO YOU NEED A TRANSFER SWITCH OR OTHER ACCESSORIES?

Parallel Power Kit (use 10/3 or 10/4 cord) with an appropriate female connector to plug into your power inlet box, transfer switch or RV. A transfer switch is required by the National Electrical Code Article 702.6 for all backup generator installations.

Transfer Switch GenTran Model 300660

or

301060

30 Amp 125V

Power Inlet Box

GenTran 05302

Or

30 amp 125/250V Power Inlet Box GenTran 14302

CORD REQUIRES

Female Conn.

GenTran Part

RJBC530

or

RJBC1430

Depending on transfer switch or power inlet box model

REQUIRES

Male Plug

50 amp 125 V GenTran Part RJBP6361 Honda Code 6363550

**Use 10/4 or 10/3 Cord **

WARNING: Hazardous voltages present when generators running. Will cause death, serious injury or substantial property damage. Shut

off generators before connecting to or disconnecting from Parallel kit. IMPORTANT: The accessories noted here are intended for 120 volt use only. Transfer switches and power inlet boxes should be installed by a qualified professional familiar with residential wiring and electrical codes. Gen/Tran accepts no responsibility for accidents caused by incorrect or in appropriate installation or use of this product.

P.O. Box 1001, Alpharetta, GA 30009

Toll Free: 1-888-GEN-TRAN

www.gen-tran.com

PN 511759 Rev A

Page 2
Image 2
GenTran 6370C manual Do YOU Need a Transfer Switch or Other ACCESSORIES?, Cord Requires