3. The indicator signal chart:

3. The indicator signal chart:

Sound and LED indicator:

 

Green LED

Power on, stand-by

 

 

 

LED signal

Red LED

Relay 1 activated

 

Yellow LED

Relay 2 activated

 

 

 

 

1 Beep

Effective PIN codes

Sound signal

2 Beeps

Entering Exiting from the Program mode

3 Beeps

Data computing error other operation mistakes

 

 

5 Beeps

Master Code reset to Factory 12345

4. Operation Instruction:

‹Enter Program Mode:

1.Compose twice the master code (Factory master is 12345)

2 beeps → you are now in the "programming mode".

2.After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 32 wrong codes attempts at the master code the lockout facility will operate.

‹Exiting from the program mode:

1.Press#to exit from the programming mode.

2.After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 32 wrong codes attempts at the master code the lockout facility will operate.

‹Add PIN codes

Enter the Programming mode, Enter the slot position code 「*001~099→?????

Input 5 digit PIN codes→ (beep) enrolled Ærepeat

Press #to exit from the programming mode, or program other operating.

Note 1: The codes00000,12345or master code are not be used for PIN code.

Note 2: Relay 1 is controlled by 001~049 user slots, Relay 2 is controlled by 050~099 user slots

‹To Delete a User Code

Enter the Programming mode→ Press the slot position code of your choice to delete (example "06") →Press「*00600000beep→deletePress#to exit from the programming mode, or programming other operating.

‹To Program Relocking Timer

Enter the Programming mode,

A.Relay 1Press「*100Followed by the number of seconds the relay should open→05=5 seconds01 ~99 = secondsbeep→enrolled → Press #to exit from the programming mode, or program other operating.

B.Enter00Sets the relay to latching mode. (Correct code entered opens the relay, and the relay stays open until the correct code is entered again).

C.Relay 2Press「*200Followed by the number of seconds the relay should open05 =5 seconds (01 ~99 = seconds). →beep→enrolled → Press #to exit from the programming mode, or program other operating.

D.Enter00Sets the relay to latching mode. (Correct code entered opens the relay, and the relay stays open until the correct code is entered again).

Copyright Gianni Industries, Inc. All Rights Reserved.

 