Gianni Industries DG-5 specifications Features, Specifications, Program Instruction

Models: DG-5

1 2
Download 2 pages 51.4 Kb
Page 1
Image 1
DG-5 The Digital Keyless Entry System

DG-5 The Digital Keyless Entry System

Operation User's Manual

1. Features:

‹ 4 digit codes 5 digit codes available by special order

‹ Tamper Switch Included

‹ Door Reed Switch Input for Anti-Trailing ‹ 10 user PINs

‹Fully Programmable via keypad and master code

‹ Non-Volatile Memory

‹ Invalid PIN Lock-out

2. Specifications:

‹ Operating Voltage:9~14 Vdc

‹ Current Draw: Average 20mA, Peak 70mA @ 12Vdc

‹ Input: One request-to-exit, and time out reed switch

‹ Relays: N.O./N.C./Com. Output (free voltage contact), 3A@ 125Vac or 30Vdc

‹ Case Material: ABS UL94V0

‹ Operating Temperature:-20~+70

‹ Ambient Humidity:0~95% relative humidity non- condensing

‹Visual Signals:

„Green: Power on

„Red: Relay activated

„Yellow: Program ModeLock-out

‹Factory Master Code: 1234

‹Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly password attempted.

‹Relay Activation Time: (*20

„Pulse mode1~99 seconds01~99

„Latching mode00

‹EPROM: Non-volatile memory, System will retain all programs and codes after a total loss of power.

‹User PINs: (*01~10It is possible to program 10 different user PIN codes.

3. Program Instruction:

‹Enter Program Mode:

1.Enter the master code twice (Factory master is 1234)

→2 beeps and the Yellow LED will light up.

you are now in the "programming mode".

2.Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.

‹Exiting from the program mode:

1.Press#to exit from the programming mode.