DG-5 The Digital Keyless Entry System
Operation User's Manual
1. Features:
4 digit codes (5 digit codes available by special order)
Tamper Switch Included
Door Reed Switch Input for
Fully Programmable via keypad and master code
Invalid PIN
2. Specifications:
Operating Voltage:9~14 Vdc
Current Draw: Average 20mA, Peak 70mA @ 12Vdc
Input: One
Relays: N.O./N.C./Com. Output (free voltage contact), 3A@ 125Vac or 30Vdc
Case Material: ABS (UL94V0)
Operating
Ambient Humidity:0~95% relative humidity non- condensing
Visual Signals:
Green: Power on
Red: Relay activated
Yellow: Program
Factory Master Code: 1234
Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly password attempted.
Relay Activation Time: (*20)
Pulse mode:1~99 seconds(01~99)
Latching mode(00)
EPROM:
User PINs: (*01~*10)It is possible to program 10 different user PIN codes.
3. Program Instruction:
Enter Program Mode:
1.Enter the master code twice (Factory master is 「1234」)
→2 beeps and the Yellow LED will light up.
→you are now in the "programming mode".
2.Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.
Exiting from the program mode:
1.Press「#」 to exit from the programming mode.
Copyright Gianni Industries, Inc. All Rights Reserved. |
|
PMUDG5 Ver. A Publish:2004.08.26 | Page: 1/ 2 |