read head should be mounted on non-metallic materials. If the unit is mounted on a metal surface the reading distance will be reduced. (Approx. 70 %)

Multiple read heads

The radiated field of the Easiprox coil extends in all directions including through brick walls. The coil of one Easiprox will interfere with another if they are mounted within 400mm of each other.

Clear SYSTEM Memory

To clear the system memory:

Remove power from the controller. Reconnect power to the controller. Short the CLEAR pins momentarily. This must be done before 5 seconds have elapsed since power up. See drawing on page 3 for position of CLEAR pins. The LEDs on the read head will flicker during the memory clear operation. When GREEN and YELLOW lamps are flashing, it indicates that the memory is empty and that there is no Master Tag. In this state the first tag read will be stored as the Master Tag.

Warning

The installer should earth himself before shorting the CLEAR jumper to avoid electrostatic discharge into the unit.

Pulse/Toggle Mode

The Easiprox relay can operate in 2 modes:

Pulse Mode

This mode is selected by selecting a pulse time 1-60 seconds. See Time Adjust programming function.

Toggle Mode

This mode is selected by selecting a pulse time >60 seconds. See Time Adjust programming function.

Deleting Tags

The MASTER tag must be used to put the 980-20 into the Delete mode.

Once in Delete mode:

RED lamp flashes. Place the Tag Simulator close to the reader. Hold down the On/Off button and check the displayed number. Press the Send button. The GREEN lamp will flash to verify that the selected number is deleted and then the RED lamp will continue flashing. Once the tag or a group of tags have been deleted, read the Master Tag to return to the RUN state.

Adding Tags

The MASTER tag must be used to put the 980-20 into the Add mode.

Once in Add mode:

GREEN lamp flashes Place the Tag Simulator close to the reader Hold down the On/Off button and check the displayed number Press the Send button The GREEN lamp will go steady and the relay will operate to verify that the selected number is added. The GREEN lamp will then continue flashing. Once the tag or a group of tags have been added, read the Master Tag to return to the RUN state.

Copyright All Rights Reserved.

 

P-MU-982-10 Ver. A Publish:2004.05.01

Page: 4/ 4

Page 4
Image 4
Gianni Industries 982-10, 981-10 Multiple read heads, Clear System Memory, Pulse/Toggle Mode, Pulse Mode, Deleting Tags

982-10, P-MU-982-10, 981-10 specifications

Gianni Industries has made a significant mark in the manufacturing sector with its range of innovative products, notably the P-MU-982-10, 982-10, and 981-10. These models are indicative of the company's commitment to quality, functionality, and advanced technology.

The P-MU-982-10 is a multifaceted unit designed for versatility in various applications. One of its standout features is its robust build quality, ensuring longevity and reliability across different environments. It is equipped with state-of-the-art sensors that enhance its operational capabilities, enabling users to monitor and manage their tasks efficiently. The model also supports seamless connectivity options, allowing integration with modern automation systems, thus making it an ideal choice for smart manufacturing processes.

Next in line is the 982-10 model, which emphasizes user-friendliness and performance. This unit boasts an intuitive interface that makes it accessible even for those with minimal technical expertise. With an emphasis on ergonomics, the design focuses on minimizing operator fatigue while boosting productivity. Its advanced processing technology enables real-time analytics, providing insights that can lead to improved decision-making and resource management.

The 981-10 model is structured for high efficiency and adaptability. It features cutting-edge energy-saving technologies that reduce operational costs significantly. In addition, components are designed for easy modular upgrades, allowing businesses to adapt to changing needs without investing in entirely new systems. Sustainability is also a focus, with materials sourced responsibly and processes that minimize environmental impact.

Across all three models, Gianni Industries integrates advanced safety protocols to protect operators and equipment alike. The inclusion of fail-safes and regular system checks ensures that these units continue to perform optimally under various conditions.

In conclusion, the P-MU-982-10, 982-10, and 981-10 from Gianni Industries are excellent representations of modern engineering, blending innovative technology with practical design. Their features significantly contribute to enhancing production efficiency, safety, and sustainability in the manufacturing sector, making them valuable assets for any industrial operation. Investing in these models not only streamlines processes but also aligns with future-oriented manufacturing goals.