Gianni Industries 982-10 Multiple read heads, Clear SYSTEM Memory, Pulse/Toggle Mode, Pulse Mode

Models: 982-10 P-MU-982-10 981-10

1 4
Download 4 pages 24.29 Kb
Page 4
Image 4
Multiple read heads

read head should be mounted on non-metallic materials. If the unit is mounted on a metal surface the reading distance will be reduced. (Approx. 70 %)

Multiple read heads

The radiated field of the Easiprox coil extends in all directions including through brick walls. The coil of one Easiprox will interfere with another if they are mounted within 400mm of each other.

Clear SYSTEM Memory

To clear the system memory:

Remove power from the controller. Reconnect power to the controller. Short the CLEAR pins momentarily. This must be done before 5 seconds have elapsed since power up. See drawing on page 3 for position of CLEAR pins. The LEDs on the read head will flicker during the memory clear operation. When GREEN and YELLOW lamps are flashing, it indicates that the memory is empty and that there is no Master Tag. In this state the first tag read will be stored as the Master Tag.

Warning

The installer should earth himself before shorting the CLEAR jumper to avoid electrostatic discharge into the unit.

Pulse/Toggle Mode

The Easiprox relay can operate in 2 modes:

Pulse Mode

This mode is selected by selecting a pulse time 1-60 seconds. See Time Adjust programming function.

Toggle Mode

This mode is selected by selecting a pulse time >60 seconds. See Time Adjust programming function.

Deleting Tags

The MASTER tag must be used to put the 980-20 into the Delete mode.

Once in Delete mode:

RED lamp flashes. Place the Tag Simulator close to the reader. Hold down the On/Off button and check the displayed number. Press the Send button. The GREEN lamp will flash to verify that the selected number is deleted and then the RED lamp will continue flashing. Once the tag or a group of tags have been deleted, read the Master Tag to return to the RUN state.

Adding Tags

The MASTER tag must be used to put the 980-20 into the Add mode.

Once in Add mode:

GREEN lamp flashes Place the Tag Simulator close to the reader Hold down the On/Off button and check the displayed number Press the Send button The GREEN lamp will go steady and the relay will operate to verify that the selected number is added. The GREEN lamp will then continue flashing. Once the tag or a group of tags have been added, read the Master Tag to return to the RUN state.

Copyright All Rights Reserved.

 