![GS-705N Shear Lock Installation Instruction](/images/new-backgrounds/50184/501841x1.webp)
GS-705N Shear Lock Installation Instruction
Unbalanced air conditioning (stack pressure) can hinder door alignment and must be corrected to help insure positive locking. It is important to note that the Shear Locks need a regulated 12V DC (or 24VDC) at the lock, and use the highest quality door closer only. Positive centering door closers are required for all double acting door applicators to help attain consistent dead center alignment. Also the door latching problems must be corrected prior to installation.
Specifications
Holding Force | Up to 2700 lbs (1226 Kg) in shear. | |
|
| |
| 12/24 VDC selectable via jumpers +10% | |
Power Input | over voltage is acceptable , under voltage | |
| will reduce holding force. | |
|
| |
Current Draw | 0.35 A@12 VDC; 0.17 A@24 VDC The unit | |
does not require initial voltage increase to | ||
| ||
| operate. | |
|
| |
Finish | M a g n e t a n d A r m a t u r e : Z i n c p l a t e d | |
| Housing: Black powder coated | |
|
| |
Monitoring Output | Magnet bond sensor output, SPDT rating | |
| 1 AMP@30 VDC | |
|
| |
Door Gap | 2mm | |
|
| |
Operating Temper. | ||
|
|
Magnet Assembly
Locking Bolt
Keep Hole
Keep Hole
Armature vertical adjustment screws
Armature Assembly
Connecting Diagram
12Vdc 24Vdc
Vo l t a g e S e l e c t i o n j u m p e r s Check jumper settings before connecting the lock to 24 VDC input power. Damage to the lock may result from incorrect jumper settings.
Magnetbond | sensoroutput |
Power | Input |
N.C.
COM.
N.O.
- +
Magnet bond sensor output | Caution: | |||||
SPDT relay : 1A@30 VDC | Make sure that the "+" and | |||||
|
|
|
|
|
| wire are connected correctly. |
|
|
|
|
|
| Failure to observe polarity will |
|
|
|
|
|
| result in a short circuit and is |
|
|
| - | Power | n o t c o v e r e d b y p r o d u c t s | |
|
|
| ||||
|
|
|
|
| warrant. | |
|
|
|
| + | supply | |
|
|
|
|
| ||
|
|
|
|
|
Control Device
N.C. contact or Access Relay
Dimensions
Install the magnet assembly into the door frame before installation the armature assembly into the door leaf. The magnet assembly requires space to run wires, as wall as space for the recesses portion of the unit. However, make sure that the position selected for the magnet assembly leaves enough room on the door to install the armature assembly.
6
GS-705N-30
32
|
| 03 |
|
| 251 |
| Locking Bolt | 267 |
| 5.9 |
|
|
| 03 |
3.5 |
| Unit: mm |
Copyright Gianni Industries, Inc. All Rights Reserved. | |
|