Gianni Industries ST-630E specifications Controller Station Setting, Anti Pass Back Function

Models: ST-630E

1 5
Download 5 pages 46.2 Kb
Page 3
Image 3
ⅣOperation Instruction:

Operation Instruction:

*xxxxxx#

 

Enter Program ModeEnter 6-digital Codes(Default 123456)

 

 

 

 

 

 

* #

 

Exit Program Mode

 

 

 

 

 

 

01*xxxxxx xxxxxx #

 

Change Default Password, Press twice new 6-digital Codes

 

 

 

 

02*xxxx #

 

Controller Station Setting

001-254

 

 

 

 

 

05*xxx#

 

Access only with the password, 0000-Unavaliable (Default, 0000)

 

 

 

10*xxxx*XXXXXXXXXX #

Adding or Revised the Cards No.

 

 

 

Slot Position =00001~01000 and enter the 10 digital Cards No.

 

 

 

12*XXXX*XXXXX#

 

Adding the batch series Cards No.. XXXX=the beginning position

 

 

*XXXXX=the quantities of the batch series card No.

 

 

(The access mode is for Card Only)

(ps. x01000)

 

 

 

 

13*xxxxx*XXXXX*N #

 

Modify the cards access parameter

 

 

 

xxxxx= The beginning slot position

 

 

 

XXXXX= the ending slot position

From=00001~01000

 

 

N is 0= Access not allow1=Card only2=Cards or Code

 

 

3=Card & Code4= Clear card information

 

 

(When modify the Mode to “Card or Code” or “ Card & Code”the

 

 

default Code is 0000.

 

 

 

 

 

 

14*xxxxx*XXXX#

 

Set the position of the Code; xxxxx=slot position XXXX=4-digital

 

Code

(Position =00001~01000)

 

 

 

 

 

 

 

15*99#

 

Clear all Cards (Not including Master Cards)

 

 

 

17*xxxxxxxxxx#

 

When forget the Cards slot positioncan clear the cards information

 

by enter Cards No..

 

 

 

 

 

 

 

 

 

 

 

 

21*xxx#

 

Alarm Time Delay Setting

xxx=000~255 Seconds

 

 

 

22*xxx#

 

Dual relays programmable time delay xxx=000~250 Seconds

 

 

(External Relay for Security System)

 

 

(000 Latched Operation)

(Default is 15 Seconds)

 

 

 

25*X#

 

Master Cards Setting x=(1 or 2). 2 Master Card available

 

 

In the normal status, proximity the Master cards to Program Mode.

 

 

 

26*xxxxx*XXXXX#

 

Security Cards arrange Setting XXXXX=00001~01000 .The arrange

 

of the No. should be continuing which can’t skip the No.

 

 

 

 

 

 

30*x#

 

x=0

General Setting Mode (Default x=0)

 

 

x=1 Card Only. Access the door by reading cards that no matter the

 

 

cards are set into the system or not.

 

 

 

 

 

 

32*x#

 

Anti Pass Back Function

 

 

 

x=0/ OFF

X=1/ ON

 

 

 

 

 

 

 

 

 

 

 

 

 

33*x#

 

Two Doors Synchronize

x=0

OFF X=1 ON Access

 

 

 

 

 

 

Copyright All Rights Reserved.

 

 

 

 

 

 

Page 3 of 5

P-MU-ST-630 Ver. A

Publish: 2009.01.08

 

 

 

Page 3
Image 3
Gianni Industries ST-630E specifications Controller Station Setting, Anti Pass Back Function, Two Doors Synchronize