![x=1= access record to duty](/images/new-backgrounds/174538/1745387x1.webp)
| Controller and Reader can open different doors. | ||
|
| ||
34*99# | Reset the function of Anti Pass Back. | ||
|
| ||
35*x# (for connecting | x=1= access record to duty | ||
x=0= access record Not to Duty | |||
controller) | |||
(x= default is 0) | |||
| |||
|
|
| |
38*x# | x=0 | Green LED is controlled by Controller x=1 Green LED is | |
| controlled by external system | ||
| (The second Relay contact to the Door Status and negatron | ||
| Green LED flash can synchronize with Security System. | ||
|
| ||
51*99# | Reset to Default, and clean the controller memory to the factory | ||
default | |||
| |||
|
| ||
55*99# | Add New Cards,read card once and 1 Beep heard for adding the | ||
| new card. Read card twice and 2 Beep heard to delete the cards. | ||
| (After add Cards,the default access mode is “Card Only”) | ||
|
|
| |
70*X# [For LCD series]X=0 | Screen Backlight ON ,x=1 Screen Backlight Off automatically | ||
|
| ||
71*XXXXXX XXXXXX # Emergent Code Setting,Enter twice | |||
| Enter the Code can link to the other relay to activate the external | ||
| system. 22*xxx # for setting the active time. (second) | ||
|
| ||
| xxx=000~255 Seconds | ||
72*xxx# | Door Left Open Alarm Time Delay - The door does not close after the | ||
| limited time, and the controller will output the alarm. | ||
|
| ||
73*x # | x=1 Enter the emergent code or press 99* with Security Cards, the | ||
relay of the controller/ ON; X=0 OFF | |||
| |||
|
| ||
74*x# | X=1 Door Left Open Alarm and Force Open Mode are ON; X=0 OFF | ||
|
| ||
76*x# | X=1 Emergent Alarm /ON,x=0 OFF | ||
|
| ||
99* | When setting or Release the External Relay, Please enter the | ||
| codes99*and then read the security card. | ||
| (Operating in the Normal Mode.) | ||
|
|
|
Ⅴ、 Wiring diagram: