Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance.

1.The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication.

2.The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joints. If pumps are to be operated at temperatures in excess of 140o F, it is important to insure a positive head to the pump to prevent cavita- tion.

3.The discharge plumbing from the pump should be properly sized to the flow rate to prevent line pres- sure loss to the work area. It is essential to provide a safety bypass valve between the pump and the work area to protect the pump from pressure spikes in the event of a blockage or the use of a shut-off gun.

4.Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although

recommended by Giant Industries, Inc. to further reduce system pulsation. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the un- loader.

5.Crankshaft rotation on Giant Industries, Inc. pumps should be made in the direction desig- nated by the arrows on the pump crankcase. Reverse rotation may be safely achieved by following a few guidelines available upon request from Giant Industries, Inc. Required horsepower for system operation can be obtained from the charts on pages 3 and 6.

6.Before beginning operation of your pumping system, remember: Check that the crankcase and seal areas have been properly lubricated per recommended schedules. Do not run the pump dry for extended periods of time. Cavitation will result in severe damage. Always remember to check that all plumbing valves are open and that pumped media can flow freely to the inlet of the pump.

Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury.

IMPORTANT OPERATING CONDITIONS Failure to comply with any of these condi- tions invalidates the warranty

1.Prior to initial operation, add oil to crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL.

Use Giant Recommended Oil (p/n 01154), or the equivalent to SAE 85-90W Industrial Grear Lube.

Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.

2.Pump operation must not exceed rated pressure, volume, or RPM. A pressure relief device must be installed in the discharge of the system.

3.Acids, alkalines, or abrasive fluids cannot be pumped unless approval in writing is obtained before operation from Giant Industries, Inc.

4.Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures.

NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600.

2

Page 2
Image 2
Giant GP7145 installation instructions Installationinstructions

GP7145 specifications

The Giant GP7145 is a high-performance bicycle that has captured the attention of cycling enthusiasts and professional riders alike. This model exemplifies innovation and quality in bike engineering, making it a standout in the competitive cycling market.

One of the primary features of the Giant GP7145 is its lightweight frame, constructed from advanced aluminum alloy. This material not only contributes to the bike's overall agility but also enhances durability and strength. Riders will appreciate the responsiveness and maneuverability that the lightweight design provides, especially during long rides or competitive events.

The GP7145 is equipped with an advanced suspension system, which includes a front fork with adjustable travel. This technology allows riders to customize their experience based on terrain and personal preference. Whether tackling rugged trails or cruising on smooth pavements, the suspension system provides optimal comfort and control, reducing fatigue during extended rides.

Another remarkable characteristic of the Giant GP7145 is its state-of-the-art gear system, featuring a high-precision, multi-speed drivetrain. This component ensures seamless shifting, allowing riders to tackle steep hills or accelerate quickly on flat roads with ease. The gear ratios are designed to cater to various riding styles, whether you are a casual rider or seeking to push your limits in competitive racing.

Braking performance is also a priority in the design of the GP7145. The bike comes with hydraulic disc brakes that offer phenomenal stopping power, enhancing safety and control in all conditions. This feature is particularly beneficial in wet or muddy environments, where reliable braking is crucial.

The GP7145 is designed with rider ergonomics in mind. The geometry of the frame allows for a comfortable riding position, reducing strain on the back and shoulders during long rides. Additionally, the bike features adjustable components such as the seat and handlebars, ensuring a perfect fit for riders of different heights and preferences.

Lastly, the aesthetic appeal of the Giant GP7145 cannot be overlooked. With a sleek design and vibrant colors, this bicycle not only performs exceptionally but also stands out visually. Overall, the Giant GP7145 encapsulates the perfect blend of technology, performance, and comfort, making it an excellent choice for a wide range of cyclists seeking quality and reliability in their rides.