Giant P208, P205 Specifications Model P206, P206 Horsepower Requirements, 1750 RPM+, 3450 RPM+

Models: P206 P208 P205

1 11
Download 11 pages 40.34 Kb
Page 4
Image 4

Specifications

 

Model P206

 

1750 RPM+

 

Ratings (Continuous)

0.8 GPM @ 2000 PSI

Ratings (Intermittent)

0.8 GPM @ 2500 PSI*

3450 RPM+

 

Ratings (Continuous)

1.5 GPM @ 2000 PSI

Ratings (Intermittent)

1.5 GPM @ 2500 PSI*

Inlet Pressure

up to 140 PSI

Plunger Diameter

12mm

Stroke

5.5mm

Temperature of Pumped Fluids

Up to 160o F

Inlet Ports

(2) 1/2" BSP

Discharge Ports

(2) 3/8" BSP

Shaft Rotation

Top of Pulley Towards Fluid End

Crankshaft Diameter

Solid, 24mm

Key Width

8mm

Shaft Mounting

Right Side Facing Manifold

Weight

11 lbs. 11oz.

Crankcase Oil Capacity

7.5 fl.oz.

Extended Crankcase Oil Capacity

9.0 fl.oz.

Volumetric Efficiency @ 1750 RPM

0.94

Volumetric Efficiency @ 3450 RPM

0.88

Mechanical Efficiency @ 3450 RPM

0.86

+Positive inlet pressure required

 

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

NOTE:

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P206 HORSEPOWER REQUIREMENTS

RPM

GPM

1000 PSI

1500 PSI

2000 PSI

2500 PSI*

250

0.11

0.1

0.1

0.2

0.2

500

0.21

0.1

0.2

0.3

0.4

1000

0.43

0.3

0.4

0.6

0.7

1750

0.76

0.5

0.8

1.0

1.3

3000

1.30

0.9

1.3

1.8

2.2

3200

1.40

1.0

1.4

1.9

2.4

3450

1.50

1.0

1.6

2.1

2.6

*Intermittent duty only

HORSEPOWER RATINGS: The rating shown are the power

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

HP = (GPM X PSI) / 1450

4

Page 4
Image 4
Giant P208, P205 installation instructions Specifications Model P206, P206 Horsepower Requirements, 1750 RPM+, 3450 RPM+