Giant P218, P219, P220, P217 Specifications Model P230, P230 HORSEPOWER REQUIREMENTS, Rpm +, Metric

Models: P227 P218 P221 P217 P219 P230 P220

1 16
Download 16 pages 49.29 Kb
Page 9
Image 9
Specifications

Specifications

Model P230

1750 RPM+

U.S

. ..............................

Metric

 

 

 

Flow (Continuous) @ 2000 PSI (140 Bar)

1.1

GPM

4.2 LPM

Flow (Intermittent) @ 2500 PSI (175 Bar)

1.1

GPM

4.2 LPM

3450 RPM+

 

 

 

Flow (Continuous) @ 2000 PSI (140 Bar)

2.0

GPM

7.8 LPM

Flow (Intermittent) @ 2500 PSI (175 Bar)

2.0

GPM

7.8 LPM

Maximum Inlet Pressure

145 PSI

10 bar

Plunger Diameter

0.71”

18 mm

Stroke

0.13”

3.4 mm

Max. Temperature of Pumped Fluids

160o F

71oC

Inlet Ports

 

(2) 1/2" BSP

Discharge Ports

 

(2) 3/8" BSP

Shaft Rotation

Top of Pulley Towards Fluid End

Crankshaft Diameter

0.98”

24 mm

Key Width

0.31”

8 mm

Shaft Mounting

Right Side Facing Manifold

Weight

11.7 lbs

5.3 Kg

Crankcase Oil Capacity

7.5

fl.oz

0.22 Liter

Extended Crankcase Oil Capacity

9.0

fl.oz

(0.27 Liter

Volumetric Efficiency @ 1750 RPM

 

0.94

Volumetric Efficiency @ 3450 RPM

 

0.87

Mechanical Efficiency @ 3450 RPM

 

0.86

+Positive inlet pressure required

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

NOTE:

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P230 HORSEPOWER REQUIREMENTS

RPM

GPM

1000 PSI

1500 PSI

2000 PSI

2500 PSI*

250

0.2

0.1

0.2

0.2

0.3

500

0.3

0.2

0.3

0.4

0.5

1000

0.6

0.4

0.7

0.9

1.1

1450

0.9

0.6

0.9

1.3

1.6

1750

1.1

0.8

1.1

1.5

1.9

3000

1.8

1.2

1.8

2.5

3.1

3200

1.9

1.3

2.0

2.6

3.3

3450

2.0

1.4

2.1

2.8

3.5

*Intermittent duty only

HORSEPOWER RATINGS: The rating shown are the power

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

HP = (GPM X PSI) / 1450

9

Page 9
Image 9
Giant P218, P219, P220, P217 Specifications Model P230, P230 HORSEPOWER REQUIREMENTS, Rpm +, Metric, Intermittent duty only