Belling Installation Instructions
Connect to the electricity supply
Warning: This appliance must be earthed.
1.The appliance must be installed by a competent electrician using a double pole control unit of 32 ampere minimum capacity, with 3mm minimum contact separation at all poles.
2.Access to the mains terminal is gained by opening the terminal block cover at the rear of the appliance (use a small
3.Connection should be made with suitable twin and earth flexible cable, minimum 4mm2, which is suitable for use up to 25 amps.
4.First strip the wires, then push the cable through the cable clamp in the terminal block cover.
5.Connect the cable to the terminal block and tighten the cable clamp screw.
6.Close the terminal box, ensuring that the cover is engaged on the locking tabs.
Check edging strip
The edging strip is factory fitted to the front side edges of the appliance front frame. This strip provides the cabinetry with extra protection from any escape of heat.
When installing the product, ensure that the edging strip is correctly located
on the outer edges of the front frame, before positioning and securing the appliance to the cabinet.
When securing the appliance, the fixing screws provided are driven through the edging strips into the cabinet - the seal will straighten up and sit flush to the cabinet when the screws are fully home.
36