II. DIMENSIONS
• | k |
It is very important that the ducts for a
I
I
/
HP MODELS
MODEL |
| A |
| B |
| C | D |
| E |
HP181D/F | 43 | 1/4 | 28/323/8 |
| 24 | 20 | 14 | 1/2 | |
HP241F | 43 | 1/4 | 32 | 3/8 |
| 24 | 21 | 14 | 1/2 |
HP301F/H | 43 | 114 | 32 | 3/8 |
| 24.- | 21 | 14 | 112 |
HP361F/H | 49 | 1/4 | 33 | 3/4 |
| 30 | 21 | 20 | 1/2 |
HP421F | 49 | 1/4 | 33 | 3/4 |
| 30 | 21 | 20 | 1/2 |
HP421H | 49 | 1/4 | 33 | 3/4 |
| 30 | 21 | 20 | 1/2 |
HP481F2/H | 57 | 3/4 | 44 | 3/8 | 30 | 1/4 | 21 | 16 | 1/4 |
HP601F2 | 57 | 3/4 | 44 | 3/8 | 30 | 1/4 | 32 | 16 | 1/4 |
HP601H | 57 | 3/4 | 44 | 3/8 | 34 | 1/4 | 32 | 16 | 1/4 |
HP662A | 57 | 3/4 | 44 | 3/8 | 34 | 114 | 34 | 23 | 112 |
|
|
|
|
| Fig. 1 |
F | G | H | J | K | L |
6 | 1 | 1 | 4/6 3/1( | 1 112 | 2 1/2 |
6 | 1 | 1 | 55/8 | 11/2 | !21/2 |
|
|
|
| i |
|
6 | 1 | 1 | 55/8 | 11/2 | 21/2 |
6 | 1 | 1 | 63/8 | 11/2 | 21/2 |
6 | 1 | 1 | 63/8 | 11/2 | 21/2 |
6 | 1 | 1 | 63/8 | 11/2 | 21/? |
10 | 1 | 1 | 63/16 | 2 | 23/4 |
10 | 1 | 1 | 63/16 | 13/4 | 23/4 |
10 | 51/4 | 1 | 63/16 | 1 3/4 | 23/4 |
7 | 1 | 1 | 51/8 | 13/4 | 23/4 |
_lJ. | III. POWER SUPPLY & WIRING |
Pages 11, 12 & 13 show typical wiring diagrams for the various units. However, each unit will have its appropriate wiring diagram attached to the access panel of the wiring control section. All wiring and fusing must comply with local and national electrical code requirernents.
The 24 volt control circuit connections are made at the right side of the panel (See fig. 1). The main power connections are made at the "L" terminals of contractor, through knockoutin side of unit. These connections must be tight and elect'ricallysecure. A fused disconnect must be weather tight. When the unit is outdoors, the fused disconnect must be installed at the unit location. The fuse(s) shouldbe
dual element type. Fuse and ampacity ratings are listed in the table on page 3 and also on the rating plate on the unit.
CAUTION: Unit must always be grounded with a suitable ground connection.