This furnace is capable fo the following heating modes:

Single Stage (Factory Setting)

Modified Two-Stage

>Fixed 5-Min. Low Stage

>Auto Time (1-12 Min.) Low Stage

To change from the factory single-stage operation, adjust the dipswitches on the ignition control as follows:

Mode

5 Min. Fixed

Auto

OFF ON

Dual $averMode Dipswitch

2nd Stage Delay Dipswitch

Note: This furnace is designed to be used

with a single-stage room thermosat.

Start

Call for Heat

Safety Circuit Check

Start Furnace in Low Stage

Low-Heat Blower

Delay Time (5 Min)

Gas Valve Switch

to 2nd Stage

Blower Switch to Hi Heat Operation

Start

Call for Heat

Safety Circuit Check

Start Furnace

in Low Stage

Low-Heat Blower

Manual background Delay Time (1-12 Min) Manual background

Gas Valve Switch

to 2nd Stage

Blower Switch to

Hi Heat Operation

T-Stat Satisfied

T-Stat Satisfied