Goodman Mfg GCH9 service manual Furnace Specifications

Models: GCH9

1 16
Download 16 pages 52.43 Kb
Page 12
Image 12

FURNACE SPECIFICATIONS

 

 

 

GCH9

 

 

 

 

 

 

 

 

 

MODEL

GCH90453BX

GCH90703BX

GCH90704BX

GCH90904CX

GCH90905CX

GCH91155DX

 

 

 

 

 

 

 

 

 

Btuh Input (US)

46,000

69,000

69,000

92,000

92,000

115,000

 

Output (US)

42,800

64,400

64,400

86,000

86,000

106,500

 

BTUH Output (US) LP

38,502

57,753

57,753

77,004

77,004

96,255

 

A.F.U.E.

93

93

93

93

93

93

 

 

 

 

 

 

 

 

 

Rated External Static (" w.c.)

.20" - .50"

.20" - .50"

.20" - .50"

.20" - .50"

.20" - .50"

.20" - .50"

 

Temperature Rise (°F)

35-65

35-65

35-65

35-65

35-65

35-65

 

 

 

 

 

 

 

 

 

Pressure Switch Trip Point (" w.c.)

-0.60

-0.60

-0.37

-0.60

-0.37

-0.60

 

Front Cover Pressure Switch Trip Point (" w.c)

-0.60

-0.60

-0.37

-0.60

-0.37

-0.60

 

 

 

 

 

 

 

 

 

Blower Wheel (D" x W")

10 X 8

10 X 8

10 X 10

10 X 10

11 X 10

11 x 10

 

Blower Horsepower

1/3

1/3

1/2

1/2

3/4

3/4

 

 

 

 

 

 

 

 

 

Blower Speeds

4

4

4

4

4

4

 

Max CFM @ 0.5 E.S.P.

1,200

1,200

1,600

1600

2000

2000

 

 

 

 

 

 

 

 

 

Power Supply

115-60-1

115-60-1

115-60-1

115-60-1

115-60-1

115-60-1

 

Minimum Circuit Ampacity (MCA)(1)

9.40

9.40

13.80

13.80

13.20

13.20

 

Maximum Overcurrent Device(2)

15

15

15

15

15

15

 

Transformer (VA)

40

40

40

40

40

40

 

Primary Limit Setting (°F)

170

170

170

150

170

155

 

Auxiliary Limit Setting (°F)

160

160

170

160

170

160

 

Rollout Limit Setting (°F)

210

210

210

220

220

210

 

 

 

 

 

 

 

 

 

Fan Delay On Heating

30

30

30

30

30

30

 

Off Heating(3)

150

150

150

150

150

150

 

Fan Delay On Cooling

5

5

5

5

5

5

 

Off Cooling

45

45

45

45

45

45

 

Fan Delay On - Fan Only

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

Gas Supply Pressure (Natural/Propane) (" w.c.)

7/11

7/11

7/11

7/11

7/11

7/11

 

Manifold Pressure (Natural/Propane)

3.5/10

3.5/10

3.5/10

3.5/10

3.5/10

3.5/10

 

Orifice Size (Natural/Propane)

43/55

43/55

43/55

43/55

43/55

43/55

 

Number of Burners

2

3

3

4

4

5

 

 

 

 

 

 

 

 

 

Vent Connector Diameter (inches) (4)

2

2

2

2

2

2

 

Shipping Weight (lbs.)

132

135

136

158

172

178

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

(2)Maximum Overcurrent Protection Device: May use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.

(3)Off Heating - this fan delay timing is adjustable (100 or 150 seconds), 150 seconds as shipped.

(4)See Installation Instructions for appropriate vent diameter, length and number of elbows.

NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.

1.These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation.

2.For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude.

3.The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufacturers method or in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures.

4.Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.

Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.

12

Page 12
Image 12
Goodman Mfg GCH9 service manual Furnace Specifications