BLOWER PERFORMANCE SPECIFICATIONS

 

 

 

 

GHS8

 

 

 

 

BLOWER PERFORMANCE

 

 

 

 

 

 

 

 

 

 

(CFM & Temperature Rise vs. External Static Pressure)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Tons AC

 

 

EXTERNAL STATIC PRESSURE (Inches Water Column)

 

 

(HeatingAs ShippedSpeed )

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at 0.5"

0.1

0.2

 

0.3

 

0.4

 

 

0.5

 

0.6

0.7

0.8

Speed

 

 

 

 

 

ESP

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

CFM

CFM

 

High

3.0

1,739

19

1,656

 

20

1,601

 

21

1,551

 

21

 

1,513

 

22

1,460

1,413

1,353

GHS8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Med

2.5

1,422

23

1,399

 

24

1,378

 

24

1,350

 

25

 

1,305

 

26

1,275

1,220

1,178

0453AXC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Med-Lo

2.0

1,207

28

1,213

 

27

1,197

 

28

1,169

 

29

 

1,158

 

29

1,131

1,103

1,068

(Med)²

 

 

 

 

 

 

Low

1.5

991

34

980

 

34

958

 

35

950

 

35

 

937

 

36

924

910

874

 

High

4.0

2,097

25

2,068

 

25

2,012

 

26

1,939

 

27

 

1,869

 

28

1,795

1,718

1,631

GHS8

Med

3.5

1,596

32

1,566

 

33

1,534

 

34

1,492

 

35

 

1,445

 

36

1,401

1,354

1288

0704BXC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Med-Lo

3.0

1,380

38

1,356

 

38

1,328

 

39

1,303

 

40

 

1,274

 

41

1,239

1,192

1127

(Med)²

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

3.0

1239

42

1191

 

44

1165

 

45

1133

 

46

 

1,104

 

47

1,082

1,040

996

 

High

5.0

2,382

28

2,315

 

29

2,234

 

30

2,158

 

31

 

2,078

 

32

1,971

1,866

1,762

GHS8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Med

4.0

1,622

41

1,603

 

42

1,583

 

42

1,556

 

43

 

1,516

 

44

1,482

1,422

1,359

0905CXC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Med-Lo

3.5

1,436

46

1,391

 

48

1,387

 

48

1,356

 

49

 

1,325

 

50

1,279

1,239

1,180

(Med)²

 

 

 

 

 

 

Low

3.0

1,240

54

1,214

 

55

1,191

 

56

1,157

 

58

 

1,120

 

60

1,083

1,052

1,025

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer.

All furnaces ship as high-speed cooling. Installer must adjust blower cooling speed as needed.

For most jobs, about 400 CFM per ton when cooling is desirable

INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.

The chart is for information only. For satisfactory operation, external static pressure must not exceed values shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating.

The dashed (---) areas indicate a temperature rise not recommended for this model.

The above chart is for U.S. furnaces installed at 0' - 2,000'. At higher altitudes, a properly de-rated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower.

13

Page 13
Image 13
Goodman Mfg GDS8 service manual Blower Performance Specifications GHS8

GHS8, GDS8 specifications

Goodman Manufacturing, a well-reputed name in the HVAC industry, offers a comprehensive range of heating and cooling solutions. Among their notable products are the GDS8, GHS8, and GMS8 series, each designed to meet diverse customer needs while providing exceptional performance and energy efficiency.

The Goodman GDS8 gas furnace is known for its remarkable efficiency and reliability. Boasting an AFUE (Annual Fuel Utilization Efficiency) rating of up to 80%, the GDS8 converts a significant portion of fuel into usable heat, ensuring lower energy bills for homeowners. This model features a multi-speed blower motor that optimizes airflow, enhancing temperature consistency throughout the home, and reducing noise levels during operation. The GDS8 comes equipped with a durable heat exchanger crafted from high-quality steel, ensuring longevity and optimal heat transfer.

On the other hand, the GHS8 series represents Goodman’s commitment to high-efficiency heating. With an AFUE rating of up to 96%, the GHS8 is engineered for maximum performance. Its two-stage heating system allows for better temperature control, enabling the furnace to operate quietly and efficiently. Another standout feature is the ComfortBridge technology, which enhances the system’s ability to communicate and adapt to the home’s specific heating needs. This feature optimizes energy usage and increases comfort levels in any environment.

The Goodman GMS8 model is an exceptional choice for homeowners looking for a reliable gas furnace with a focus on energy efficiency. Similar to its counterparts, the GMS8 also delivers an AFUE of up to 96.5%. This unit features an advanced modulating gas valve that adjusts heating output based on the temperature requirements, creating a consistent and comfortable indoor climate. The GMS8 is also equipped with a high-efficiency ECM blower motor, which reduces energy consumption while improving airflow.

All three models feature Goodman’s quality construction, including a heavy-gauge cabinet that minimizes noise and enhances durability. They also are backed by Goodman’s limited lifetime warranty on the heat exchanger and a 10-year limited warranty on parts, providing customers with peace of mind regarding their investment. These furnaces are designed with efficiency and comfort in mind, making the GDS8, GHS8, and GMS8 ideal choices for homeowners looking to enhance their indoor environment while keeping energy costs in check.