Product Specifications

Specifications

GPH14

24H41A*

GPH14

30H41A*

GPH14

36H41A*

GPH14

42H41A*

GPH14

48H41A*

GPH14

60H41A*

Cooling Capacity

AHRI Cooling Capacity (BTU/h)

24,400

29,600

36,000

40,000

46,000

57,000

Sensible BTU/h

18,200

23,400

27,400

29,600

35,400

40,500

SEER / EER

15.0 / 12.2

14.5 / 12.2

14.3 / 12

14.2 / 12

14.5 / 12.1

14.2 / 12

Decibels

76

76

78

78

80

80

AHRI Numbers

4385132

4385133

4385134

4385135

4385136

4385137

Heating Capacity

BTU/h (47°F)

C.O.P. (47°F)

BTU/h (17°F)

C.O.P. (17°F)

HSPF

22,800

27,600

33,000

37,600

45,000

54,500

3.8

3.8

3.7

3.8

3.9

3.6

13,000

15,400

21,400

21,600

26,000

33,800

2.4

2.5

2.4

2.4

2.4

2.5

8.0

8.3

8.5

8.3

8.3

8.4

Evaporator Motor

Type

EEM

EEM

EEM

EEM

EEM

EEM

Wheel (D x W)

10 x 8

10 x 8

10 x 8

10 x 8

10 x 8

11 x 8

Cooling CFM

850

1,050

1,200

1,300

1,600

1,600

Fan-Only CFM

800

950

1,100

1,200

1,400

1,600

RLA

1.5

1.86

1.86

2.9

2.9

2.9

No. of Speeds

5

5

5

5

5

5

Horsepower - RPM

½ - 1,050

½ - 1,050

½ - 1,050

½ - 1,050

¾ - 1,050

¾ - 1,050

Evaporator Coil

 

 

 

 

 

 

Face Area (ft2)

5.25

4.67

5.2

6.2

6.2

7.0

Rows Deep/ Fins per Inch

3/ 16

4/ 16

3/ 14

4/ 14

4/ 14

4/ 14

Indoor Metering Device Size

0.057

0.065

0.068

0.072

0.076

0.088

Filter Size (ft2)

20 x 20 x 1

20 x 25 x 1

25 x 25 x 1

(2) 20 x 20 x 1

(2) 20 x 20 x 1

(2) 20 x 25 x 1

Drain Size (NPT)

¾"

¾"

¾"

¾"

¾"

¾"

Refrigerant Charge (oz.)

85

105

125

150

190

200

Condenser Fan / Coil

 

 

 

 

 

 

Horsepower - RPM

1/6 - 815

1/6 - 815

¼ - 1075

¼ - 1075

¼ - 1075

¼ - 1075

RLA/LRA

1.1 / 1.7

1.1 / 1.7

1.5 /3.0

1.4 / 2.9

1.4 / 2.9

1.4 / 2.9

Fan Diameter / # Fan Blades

22 / 3

22 / 3

22 / 4

22 / 4

22 / 4

22 / 4

Face Area (ft2)

13.4

13.4

17

17

19.1

19.1

Outdoor Metering Device Size

0.049

0.047

0.067

0.065

0.065

0.071

Rows Deep/ Fins per Inch

1 / 24

1 / 24

1 / 24

1 / 24

2 / 16

2 / 16

Compressor

Quantity

Type

Stage

1

1

1

1

1

1

Scroll

Scroll

Scroll

Scroll

Scroll

Scroll

Single

Single

Single

Single

Single

Single

Electrical Data

Voltage/Phase/ Frequency

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

Compressor RLA/LRA

12.8 / 58.3

14.1 / 73

16.7 / 79

17.9 / 112

19.9 / 109

26.4 / 134

Indoor Blower FLA

1.5

1.86

1.86

2.9

2.9

2.9

Outdoor Fan RLA

1.1

1.1

1.4

1.4

1.4

1.4

Total Unit Amps

15.4

17.06

19.96

22.2

24.2

30.7

Min. Circuit Ampacity¹

18.6

20.6

24.2

26.6

29.2

40.2

Min. Overcurrent Protection (amps)²

30

30

40

40

45

60

Ship Weight (lbs)

325

325

385

385

415

415

Operating Weight (lbs)

315

315

375

375

405

405

¹Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

Note: Always check the S&R plate for electrical data on the unit being installed.

SS-GPH14H

www.goodmanmfg.com

3

Page 3
Image 3
Goodman Mfg GPH14H dimensions Specifications, 60H41A