Product Specifications
Specifications
GPH14
24H41A*
GPH14
30H41A*
GPH14
36H41A*
GPH14
42H41A*
GPH14
48H41A*
GPH14
60H41A*
Cooling Capacity
AHRI Cooling Capacity (BTU/h) | 24,400 | 29,600 | 36,000 | 40,000 | 46,000 | 57,000 |
Sensible BTU/h | 18,200 | 23,400 | 27,400 | 29,600 | 35,400 | 40,500 |
SEER / EER | 15.0 / 12.2 | 14.5 / 12.2 | 14.3 / 12 | 14.2 / 12 | 14.5 / 12.1 | 14.2 / 12 |
Decibels | 76 | 76 | 78 | 78 | 80 | 80 |
AHRI Numbers | 4385132 | 4385133 | 4385134 | 4385135 | 4385136 | 4385137 |
Heating Capacity
BTU/h (47°F)
C.O.P. (47°F)
BTU/h (17°F)
C.O.P. (17°F)
HSPF
22,800 | 27,600 | 33,000 | 37,600 | 45,000 | 54,500 |
3.8 | 3.8 | 3.7 | 3.8 | 3.9 | 3.6 |
13,000 | 15,400 | 21,400 | 21,600 | 26,000 | 33,800 |
2.4 | 2.5 | 2.4 | 2.4 | 2.4 | 2.5 |
8.0 | 8.3 | 8.5 | 8.3 | 8.3 | 8.4 |
Evaporator Motor
Type | EEM | EEM | EEM | EEM | EEM | EEM |
Wheel (D x W) | 10 x 8 | 10 x 8 | 10 x 8 | 10 x 8 | 10 x 8 | 11 x 8 |
Cooling CFM | 850 | 1,050 | 1,200 | 1,300 | 1,600 | 1,600 |
800 | 950 | 1,100 | 1,200 | 1,400 | 1,600 | |
RLA | 1.5 | 1.86 | 1.86 | 2.9 | 2.9 | 2.9 |
No. of Speeds | 5 | 5 | 5 | 5 | 5 | 5 |
Horsepower - RPM | ½ - 1,050 | ½ - 1,050 | ½ - 1,050 | ½ - 1,050 | ¾ - 1,050 | ¾ - 1,050 |
Evaporator Coil |
|
|
|
|
|
|
Face Area (ft2) | 5.25 | 4.67 | 5.2 | 6.2 | 6.2 | 7.0 |
Rows Deep/ Fins per Inch | 3/ 16 | 4/ 16 | 3/ 14 | 4/ 14 | 4/ 14 | 4/ 14 |
Indoor Metering Device Size | 0.057 | 0.065 | 0.068 | 0.072 | 0.076 | 0.088 |
Filter Size (ft2) | 20 x 20 x 1 | 20 x 25 x 1 | 25 x 25 x 1 | (2) 20 x 20 x 1 | (2) 20 x 20 x 1 | (2) 20 x 25 x 1 |
Drain Size (NPT) | ¾" | ¾" | ¾" | ¾" | ¾" | ¾" |
Refrigerant Charge (oz.) | 85 | 105 | 125 | 150 | 190 | 200 |
Condenser Fan / Coil |
|
|
|
|
|
|
Horsepower - RPM | 1/6 - 815 | 1/6 - 815 | ¼ - 1075 | ¼ - 1075 | ¼ - 1075 | ¼ - 1075 |
RLA/LRA | 1.1 / 1.7 | 1.1 / 1.7 | 1.5 /3.0 | 1.4 / 2.9 | 1.4 / 2.9 | 1.4 / 2.9 |
Fan Diameter / # Fan Blades | 22 / 3 | 22 / 3 | 22 / 4 | 22 / 4 | 22 / 4 | 22 / 4 |
Face Area (ft2) | 13.4 | 13.4 | 17 | 17 | 19.1 | 19.1 |
Outdoor Metering Device Size | 0.049 | 0.047 | 0.067 | 0.065 | 0.065 | 0.071 |
Rows Deep/ Fins per Inch | 1 / 24 | 1 / 24 | 1 / 24 | 1 / 24 | 2 / 16 | 2 / 16 |
Compressor
Quantity
Type
Stage
1 | 1 | 1 | 1 | 1 | 1 |
Scroll | Scroll | Scroll | Scroll | Scroll | Scroll |
Single | Single | Single | Single | Single | Single |
Electrical Data
Voltage/Phase/ Frequency | ||||||
Compressor RLA/LRA | 12.8 / 58.3 | 14.1 / 73 | 16.7 / 79 | 17.9 / 112 | 19.9 / 109 | 26.4 / 134 |
Indoor Blower FLA | 1.5 | 1.86 | 1.86 | 2.9 | 2.9 | 2.9 |
Outdoor Fan RLA | 1.1 | 1.1 | 1.4 | 1.4 | 1.4 | 1.4 |
Total Unit Amps | 15.4 | 17.06 | 19.96 | 22.2 | 24.2 | 30.7 |
Min. Circuit Ampacity¹ | 18.6 | 20.6 | 24.2 | 26.6 | 29.2 | 40.2 |
Min. Overcurrent Protection (amps)² | 30 | 30 | 40 | 40 | 45 | 60 |
Ship Weight (lbs) | 325 | 325 | 385 | 385 | 415 | 415 |
Operating Weight (lbs) | 315 | 315 | 375 | 375 | 405 | 405 |
¹Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² Must use
Note: Always check the S&R plate for electrical data on the unit being installed.