Goodman Mfg warranty Expanded Heating Data cont, Product Specifications, SS-GPH15M

Models: GPH15M

1 40
Download 40 pages 50.83 Kb
Page 31
Image 31
Expanded Heating Data (cont.)

Product Specifications

Expanded Heating Data (cont.)

GPH1542M41A*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

50.3

47.6

44.8

41.9

40.0

38.8

36.0

33.2

24.9

23.0

21.2

20.0

19.3

17.3

15.3

13.4

11.4

9.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

∆T

37.2

35.3

33.2

31.0

29.6

28.7

26.7

24.6

18.5

17.0

15.7

14.8

14.3

12.8

11.3

9.9

8.4

6.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

3.42

3.35

3.28

3.21

3.17

3.14

3.07

3.00

2.89

2.82

2.75

2.71

2.68

2.61

2.55

2.48

2.41

2.35

Amps

16.8

15.6

14.7

13.9

13.4

13.2

12.5

11.9

11.4

10.9

10.5

10.2

10.1

9.7

9.1

8.6

8.0

7.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COP

4.31

4.16

4.00

3.82

3.70

3.61

3.43

3.24

2.53

2.39

2.25

2.16

2.10

1.93

1.76

1.58

1.38

1.16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

14.7

14.2

13.7

13.1

12.6

12.3

11.7

11.1

8.6

8.2

7.7

7.4

7.2

6.6

6.0

5.4

4.7

4.0

HI PR

402

385

371

354

346

339

326

313

300

286

275

268

264

254

244

234

226

218

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

135

126

118

108

102

98

90

80

73

65

57

53

51

43

37

31

27

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPH1543M41A*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

50.2

47.5

44.7

41.8

39.9

38.7

35.9

33.1

23.2

21.4

19.7

18.6

17.9

16.1

14.3

12.4

10.6

8.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

∆T

38.7

36.6

34.5

32.2

30.8

29.8

27.7

25.6

17.9

16.5

15.2

14.4

13.8

12.4

11.0

9.6

8.2

6.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

3.45

3.38

3.31

3.24

3.20

3.17

3.10

3.03

2.43

2.37

2.32

2.29

2.26

2.21

2.15

2.10

2.04

1.99

Amps

18.5

17.3

16.3

15.5

15.0

14.8

14.0

13.4

12.9

12.5

12.0

11.7

11.6

11.1

10.5

10.0

9.4

8.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COP

4.25

4.11

3.95

3.77

3.65

3.57

3.39

3.20

2.80

2.64

2.49

2.38

2.32

2.13

1.94

1.73

1.52

1.28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

14.5

14.0

13.5

12.9

12.5

12.2

11.6

10.9

9.6

9.0

8.5

8.1

7.9

7.3

6.6

5.9

5.2

4.4

HI PR

413

395

380

364

355

348

335

321

308

294

282

275

271

260

250

240

231

223

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

143

133

125

114

108

104

96

85

77

69

60

56

54

46

39

33

29

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPH1548M41A*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

40.0

37.8

35.6

33.3

31.8

30.8

28.6

26.4

21.8

20.1

18.5

17.5

16.9

15.1

13.4

11.7

10.0

8.2

∆T

30.8

29.2

27.5

25.7

24.5

23.8

22.1

20.4

16.8

15.5

14.3

13.5

13.0

11.7

10.3

9.0

7.7

6.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

3.04

2.98

2.92

2.86

2.83

2.80

2.74

2.69

2.81

2.74

2.68

2.64

2.62

2.55

2.49

2.43

2.36

2.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

11.5

10.8

10.2

9.7

9.4

9.3

8.8

8.5

8.2

7.9

7.6

7.5

7.4

7.1

6.8

6.5

6.1

5.7

COP

3.85

3.72

3.57

3.41

3.29

3.22

3.05

2.88

2.27

2.15

2.02

1.94

1.88

1.73

1.58

1.41

1.24

1.04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

13.1

12.7

12.2

11.6

11.2

11.0

10.4

9.8

7.8

7.3

6.9

6.6

6.4

5.9

5.4

4.8

4.2

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

395

379

364

348

340

334

321

308

295

282

270

264

259

249

240

230

222

214

LO PR

139

129

121

111

105

101

93

83

75

67

59

54

52

44

38

32

28

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPH1548M41A*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

57.4

54.3

51.1

47.8

45.7

44.2

41.1

37.9

30.7

28.3

26.1

24.6

23.7

21.3

18.8

16.4

14.0

11.5

∆T

31.3

29.6

27.8

26.0

24.9

24.1

22.4

20.6

16.7

15.4

14.2

13.4

12.9

11.6

10.3

9.0

7.6

6.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

4.20

4.12

4.04

3.96

3.92

3.88

3.81

3.73

3.66

3.58

3.50

3.45

3.42

3.34

3.26

3.19

3.11

3.03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

20.6

19.2

18.2

17.2

16.7

16.4

15.6

15.0

14.4

13.9

13.3

13.1

12.9

12.4

11.7

11.2

10.5

9.7

COP

4.00

3.86

3.70

3.53

3.41

3.34

3.16

2.98

2.45

2.32

2.18

2.09

2.03

1.86

1.69

1.51

1.32

1.11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

13.7

13.2

12.7

12.1

11.7

11.4

10.8

10.2

8.4

7.9

7.4

7.1

6.9

6.4

5.8

5.2

4.5

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

411

394

379

363

354

347

334

320

307

293

282

275

270

260

250

239

231

223

LO PR

131

122

114

105

99

95

88

78

70

63

55

51

50

42

36

30

27

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Above information is for nominal CFM and 70-degree indoor dry bulb. Instantaneous capacity listed.

 

 

 

 

 

 

 

High pressure is measured at the liquid line access fitting.

 

 

 

Amps: Unit amps (comp.+ evaporator motor + condenser fan motor)

Low pressure is measured at the compressor suction access fitting.

 

 

 

 

 

 

 

kW = Total system power