Product Specifications
Specifications
| GSC13 | GSC13 | GSC13 | GSC13 | GSC13 | GSC13 | GSC13 |
| 0181G* | 0241F* | 0301E* | 0361G* | 0421C* | 0481C* | 0601D* |
|
|
|
|
|
|
|
|
Cooling Capacities |
|
|
|
|
|
|
|
Tonnage | 1½ | 2 | 2½ | 3 | 3½ | 4 | 5 |
Decibels | 76 | 76 | 72 | 75 | 76 | 76 | 77 |
|
|
|
|
|
|
|
|
Compressor |
|
|
|
|
|
|
|
RLA | 6.8 | 10.8 | 13.5 | 13.4 | 15.4 | 19.2 | 21.8 |
LRA | 40 | 56 | 68 | 74 | 87 | 112 | 137 |
|
|
|
|
|
|
|
|
Condenser Fan Motor |
|
|
|
|
|
|
|
Horsepower | 1/8 | 1/8 | 1/8 | 1/6 | ¼ | ¼ | ¼ |
FLA | 0.65 | 0.65 | 0.7 | 1.1 | 1.5 | 1.5 | 1.5 |
|
|
|
|
|
|
|
|
Refrigeration System |
|
|
|
|
|
|
|
Refrigerant Line Size |
|
|
|
|
|
|
|
Liquid Line Size (“O.D.) | ⅜" | ⅜" | ⅜" | ⅜" | ⅜" | ⅜" | ⅜" |
Suction Line Size (“O.D.) | ¾" | ¾" | ¾" | ⅞" | 1⅛" | 1⅛" | 1⅛" |
Refrigerant Connection Size |
|
|
|
|
|
|
|
Liquid Valve Size (“O.D.) | ⅜" | ⅜" | ⅜" | ⅜" | ⅜" | ⅜" | ⅜" |
Suction Valve Size (“O.D.) ³ | ¾" | ¾" | ¾" | ¾" ³ | ¾" ³ | ⅞" 4 | ⅞" 4 |
Valve Type | Sweat | Sweat | Sweat | Sweat | Sweat | Sweat | Sweat |
Refrigerant Charge | 87 | 77 | 66 | 77 | 108 | 128 | 118 |
|
|
|
|
|
|
|
|
Electrical Data |
|
|
|
|
|
|
|
AC | |||||||
Min. Circuit Ampacity¹ | 9.2 | 14.2 | 17.6 | 17.9 | 20.8 | 25.5 | 28.8 |
Max. Overcurrent Device² | 15 | 25 | 30 | 30 | 35 | 40 | 50 |
Min / Max Volts | 197/253 | 197/253 | 197/253 | 197/253 | 197/253 | 197/253 | 197/253 |
Electrical Conduit Size | ½" or ¾" | ½" or ¾" | ½" or ¾" | ½" or ¾" | ½" or ¾" | ½" or ¾" | ½" or ¾" |
|
|
|
|
|
|
|
|
Equipment Weight (lbs) | 116 | 116 | 142 | 141 | 141 | 176 | 207 |
Ship Weight (lbs) | 130 | 130 | 159 | 159 | 159 | 194 | 225 |
|
|
|
|
|
|
|
|
¹Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ² Must use
³ Installer will need to supply ¾” to ⅞” adapters for suction line connections. ⁴ Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
Notes
•Always check the S&R plate for electrical data on the unit being installed.
•Charge with refrigerant charge listed on S&R plate; 15’ of ⅜” line included in this charge. System charge must be adjusted per Installation Instructions Final Charge Procedure.
www.goodmanmfg.com | 3 |