Goodman Mfg PC50 Expanded Cooling Ratings, PC048-5G, PC060-5G, Product Specifications, 50.7

Models: PC50

1 8
Download 8 pages 57.89 Kb
Page 4
Image 4
EXPANDED COOLING RATINGS

PRODUCT SPECIFICATIONS

EXPANDED COOLING RATINGS

PC048-5G

Indoor

 

 

 

 

 

Condenser Air Temperature

 

 

 

 

 

Air

 

75

 

 

85

 

 

95

 

 

105

 

 

115

 

SCFM

WB

Total

Sens

Watts

Total

Sens

Watts

Total

Sens

Watts

Total

Sens

Watts

Total

Sens

Watts

MBTU

MBTU

kWh

MBTU

MBTU

kWh

MBTU

MBTU

kWh

MBTU

MBTU

kWh

MBTU

MBTU

kWh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

48.1

23.5

4.05

46.9

23.6

4.32

45.8

23.7

4.56

43.5

23.4

4.76

40.3

21.8

4.93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1194

67

45.0

29.5

3.92

43.9

29.5

4.18

42.8

29.7

4.41

40.7

29.3

4.60

37.7

27.3

4.77

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

42.1

33.9

3.80

41.1

33.9

4.04

40.1

34.1

4.26

38.1

33.7

4.45

35.3

31.4

4.61

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

59

41.2

35.3

3.71

40.2

35.4

3.96

39.2

35.6

4.17

37.3

35.1

4.35

34.5

32.8

4.50

 

71

52.1

26.4

4.16

50.8

26.5

4.44

49.6

26.7

4.68

47.1

26.3

4.89

43.6

24.6

5.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1365

67

48.7

33.1

4.02

47.6

33.1

4.29

46.4

33.4

4.52

44.1

32.9

4.72

40.8

30.7

4.89

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

45.6

38.1

3.90

44.5

38.1

4.15

43.4

38.4

4.37

41.3

37.8

4.57

38.2

35.3

4.73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

59

44.6

39.7

3.81

43.6

39.8

4.06

42.5

40.0

4.28

40.4

39.5

4.46

37.4

36.9

4.62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

53.6

28.6

4.20

52.4

28.6

4.47

51.1

28.8

4.72

48.5

28.4

4.93

45.0

26.5

5.11

1536

67

50.2

35.7

4.06

49.0

35.8

4.33

47.8

36.0

4.56

45.4

35.5

4.76

42.1

33.2

4.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

47.0

41.1

3.93

45.9

41.1

4.19

44.7

41.4

4.41

42.5

40.9

4.61

39.4

38.2

4.77

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

59

46.0

42.9

3.84

44.9

42.9

4.09

43.8

43.8

4.31

41.6

41.6

4.50

38.5

38.5

4.66

Sensible heat capacities shown are based on 80°F DB entering air at the evaporator coil.

For sensible heat capacities at other than 80°F DB, deduct 84 BTU/h per 100 CFM of evaporator coil air for each degree below 80°F, or add 84 BTU/h per 100 CFM of evaporator coil air per degree above 80°F.

Total MBTU/h 43.0 Sensible MBTU/h 33.0 Latent MBTU/h 10.0

PC060-5G

Indoor

 

 

 

 

 

Condenser Air Temperature

 

 

 

 

 

Air

 

 

75

 

 

85

 

 

95

 

 

105

 

 

115

 

SCFM

WB

Total

Sens

Watts

Total

Sens

Watts

Total

Sens

Watts

Total

Sens

Watts

Total

Sens

Watts

MBTU

MBTU

kWh

MBTU

MBTU

kWh

MBTU

MBTU

kWh

MBTU

MBTU

kWh

MBTU

MBTU

kWh

 

 

71

56.7

27.7

5.23

55.3

27.8

5.57

54.0

28.0

5.87

51.3

27.6

6.12

47.5

25.8

6.35

1481

 

67

53.0

34.7

5.06

51.8

34.8

5.39

50.5

35.0

5.68

48.0

34.5

5.92

44.4

32.2

6.13

 

63

49.6

39.9

4.90

48.4

40.0

5.21

47.3

40.3

5.49

44.9

39.7

5.73

41.6

37.1

5.93

 

 

 

 

59

48.6

41.7

4.79

47.4

41.7

5.10

46.2

42.0

5.37

43.9

41.4

5.60

40.7

38.7

5.80

 

 

71

61.4

31.2

5.36

59.9

31.2

5.71

58.5

31.4

6.02

55.6

31.0

6.29

51.5

28.9

6.52

1693

 

67

57.4

39.0

5.19

56.1

39.1

5.53

54.7

39.3

5.83

52.0

38.8

6.08

48.1

36.2

6.30

 

63

53.8

44.9

5.02

52.5

44.9

5.35

51.2

45.2

5.64

48.6

44.6

5.88

45.1

41.7

6.09

 

 

 

 

59

52.6

46.8

4.92

51.4

46.9

5.23

50.1

47.2

5.51

47.6

46.5

5.75

44.1

43.5

5.95

 

 

71

63.2

33.7

5.41

61.7

33.7

5.76

60.2

33.9

6.08

57.2

33.5

6.34

53.0

31.3

6.57

1905

 

67

59.2

42.1

5.23

57.7

42.2

5.57

56.3

42.5

5.87

53.5

41.9

6.13

49.6

39.1

6.35

 

63

55.4

48.5

5.07

54.1

48.5

5.39

52.7

48.8

5.68

50.1

48.2

5.93

46.4

45.0

6.14

 

 

 

 

59

54.2

50.6

4.96

52.9

50.6

5.28

51.6

51.6

5.56

49.0

49.0

5.80

45.4

45.4

6.01

Sensible heat capacities shown are based on 80°F DB entering air at the evaporator coil.

For sensible heat capacities at other than 80°F DB, deduct 84 BTU/h per 100 CFM of evaporator coil air for each degree below 80°F, or add 84 BTU/h per 100 CFM of evaporator coil air per degree above 80°F.

Total MBTU/h

50.7

Sensible MBTU/h 38.9

Latent MBTU/h 11.8

4

www.goodmanmfg.com

SS-PC50

Page 4
Image 4