Goodman Mfg SS-DSZC18 dimensions Product Specifications

Models: SS-DSZC18

1 32
Download 32 pages 59 Kb
Page 3
Image 3
Specifications

Product Specifications

Specifications

DSZC18

0361A

DSZC18

0481A

DSZC18

0601A

DSZC18

0601B

Cooling Capacity

Nominal Cooling (BTU/h)

35,000

47,000

57,000

57,000

 

 

 

 

 

Nominal Heating (BTU/h)

35,000

47,000

57,000

57,000

 

 

 

 

 

Decibels

72

73

75

75

 

 

 

 

 

Compressor

 

 

 

 

RLA

LRA

16.7

21.2

25.6

23.0

82

96

118

118

 

 

 

 

Condenser Fan Motor

Horsepower (RPM)

 

 

 

 

 

FLA

2.8

2.8

2.8

2.8

 

 

 

 

 

Refrigeration System

 

 

 

 

 

 

 

 

 

Refrigerant Line Size¹

 

 

 

 

 

 

 

 

 

Liquid Line Size (“O.D.)

⅜"

⅜"

⅜"

⅜"

 

 

 

 

 

Suction Line Size (“O.D.)

⅞"

1⅛"

1⅛"

1⅛"

 

 

 

 

 

Refrigerant Connection Size

 

 

 

 

 

 

 

 

 

Liquid Valve Size (“O.D.)

⅜"

⅜"

⅜"

⅜"

 

 

 

 

 

Suction Valve Size (“O.D.)

⅞"

1⅛"

1⅛"

1⅛"

 

 

 

 

 

Valve Connection Type

Sweat

Sweat

Sweat

Sweat

 

 

 

 

 

Refrigerant Charge

188

278

278

278

 

 

 

 

 

Expansion Device

TXV

TXV

TXV

TXV

 

 

 

 

 

Superheat at Service Valve

7-9°F

7-9°F

7-9°F

7-9°F

 

 

 

 

 

Subcooling at Service Valve

 

 

 

 

 

 

 

 

 

High Stage

8-10°F

8-10°F

8-10°F

8-10°F

 

 

 

 

 

Low Stage

5-7°F

5-7°F

5-7°F

5-7°F

 

 

 

 

 

Electrical Data

 

 

 

 

 

 

 

 

 

Voltage-Phase-Hz

208/230-1-60

208/230-1-60

208/230-1-60

208/230-1-60

 

 

 

 

 

Minimum Circuit Ampacity ²

23.7

29.3

34.8

31.6

 

 

 

 

 

Max. Overcurrent Protection ³

40

50

60

50

 

 

 

 

 

Min / Max Volts

197 / 253

197 / 253

197 / 253

197 / 253

 

 

 

 

 

Electrical Conduit Size

½" or ¾"

½" or ¾"

½" or ¾"

½" or ¾"

 

 

 

 

 

Ship Weight (lbs)

293

340

360

360

 

 

 

 

 

¹ Tested and rated in accordance with ARI Standard 210/240

²Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.

Notes

Always check the rating plate for electrical data on the unit being installed.

Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.

Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.

Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT,

NOT THE INDOOR COIL.

SS-DSZC18

www.goodmanmfg.com

3