Goodman Mfg SS-DSZC18 dimensions Expanded Heating Data, Product Specifications

Models: SS-DSZC18

1 32
Download 32 pages 59 Kb
Page 20
Image 20
Expanded Heating Data

Product Specifications

Expanded Heating Data

DSZC180361A* / CA*F3642C6A*+TXV/ MBE1600**-1 — High Stage

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

44.5

42.2

39.7

37.1

35.4

34.3

31.9

29.4

27.5

25.4

23.4

22.0

21.2

19.1

16.9

14.7

12.6

10.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

∆T

33.0

31.2

29.4

27.5

26.2

25.4

23.6

21.8

20.4

18.8

17.3

16.3

15.7

14.1

12.5

10.9

9.3

7.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

2.81

2.75

2.69

2.63

2.6

2.57

2.52

2.46

2.43

2.37

2.32

2.28

2.26

2.20

2.14

2.08

2.02

1.97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

12.8

11.8

11.1

10.4

10.0

9.8

9.2

8.7

8.3

8.0

7.6

7.4

7.3

6.9

6.4

6.0

5.5

4.9

COP

4.64

4.49

4.32

4.12

3.99

3.90

3.71

3.50

3.30

3.13

2.95

2.83

2.75

2.54

2.31

2.07

1.82

1.53

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

15.9

15.3

14.8

14.1

13.6

13.3

12.7

12.0

11.3

10.7

10.1

9.7

9.4

8.7

7.9

7.1

6.2

5.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

400

383

369

352

344

338

324

311

298

285

274

267

262

252

243

233

224

216

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

143

132

124

114

108

104

95

85

77

68

60

56

54

46

39

33

29

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSZC180361A* / CA*F3642C6A*+TXV/ MBE1600**-1 — Low Stage

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

30.8

29.2

27.4

25.6

24.5

23.7

22.0

20.3

18.0

16.6

15.3

14.5

13.9

12.5

11.1

9.7

8.3

6.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

∆T

33.5

31.8

29.9

27.9

26.7

25.9

24.0

22.1

19.6

18.1

16.7

15.8

15.2

13.6

12.1

10.5

9.0

7.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

1.98

1.94

1.90

1.86

1.8

1.81

1.77

1.73

1.78

1.74

1.69

1.67

1.65

1.60

1.56

1.51

1.47

1.42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

9.5

8.8

8.2

7.7

7.5

7.3

6.9

6.5

6.2

6.0

5.7

5.5

5.5

5.2

4.8

4.5

4.2

3.7

COP

4.54

4.39

4.23

4.04

3.91

3.83

3.64

3.44

2.96

2.81

2.65

2.54

2.48

2.28

2.08

1.87

1.64

1.39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

15.5

15.0

14.4

13.8

13.4

13.1

12.4

11.7

10.1

9.6

9.1

8.7

8.5

7.8

7.1

6.4

5.6

4.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

393

377

362

346

338

332

319

306

293

280

269

262

258

248

238

229

221

213

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

145

134

126

116

109

105

97

86

78

69

61

57

55

46

40

34

29

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSZC180481A* / CA*F4860*6A*+TXV/ MBE2000**-1 — High Stage

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

62.2

58.9

55.4

51.8

49.5

48.0

44.6

41.1

38.9

35.9

33.0

31.2

30.0

27.0

23.9

20.8

17.8

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

∆T

32.9

31.2

29.3

27.4

26.2

25.4

23.6

21.7

20.6

19.0

17.5

16.5

15.9

14.3

12.6

11.0

9.4

7.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

3.80

3.72

3.64

3.56

3.5

3.49

3.41

3.33

3.28

3.20

3.12

3.07

3.04

2.96

2.89

2.81

2.73

2.66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

17.0

15.7

14.7

13.8

13.2

13.0

12.2

11.5

11.0

10.5

10.0

9.7

9.6

9.1

8.4

7.9

7.2

6.4

COP

4.80

4.64

4.46

4.26

4.12

4.03

3.82

3.61

3.47

3.29

3.10

2.97

2.89

2.66

2.42

2.17

1.90

1.61

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

16.4

15.8

15.2

14.5

14.1

13.8

13.1

12.3

11.9

11.2

10.6

10.2

9.9

9.1

8.3

7.4

6.5

5.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

398

382

367

351

343

336

323

310

297

284

272

266

261

251

241

232

223

215

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

137

127

119

109

103

99

91

81

73

65

57

53

51

44

38

32

28

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSZC180481A* / CA*F4860*6A*+TXV/ MBE2000**- — Low Stage

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

43.8

41.4

39.0

36.5

34.8

33.7

31.3

28.9

27.0

25.0

23.0

21.7

20.9

18.7

16.6

14.5

12.4

10.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

∆T

33.8

32.0

30.1

28.1

26.9

26.0

24.2

22.3

20.9

19.3

17.7

16.7

16.1

14.5

12.8

11.2

9.5

7.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

2.67

2.62

2.56

2.50

2.5

2.44

2.39

2.33

2.44

2.38

2.32

2.28

2.26

2.19

2.13

2.07

2.01

1.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Amps

12.7

11.7

10.9

10.2

9.8

9.6

9.0

8.5

8.1

7.7

7.2

7.0

6.9

6.5

6.0

5.6

5.1

4.5

COP

4.79

4.63

4.46

4.27

4.13

4.04

3.84

3.63

3.24

3.07

2.90

2.78

2.71

2.50

2.28

2.05

1.80

1.52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EER

16.4

15.8

15.2

14.6

14.1

13.8

13.1

12.4

11.1

10.5

9.9

9.5

9.3

8.5

7.8

7.0

6.2

5.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

391

375

360

344

336

330

317

304

292

278

267

261

256

247

237

227

219

212

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO PR

145

134

126

115

109

105

97

86

78

69

61

57

55

46

40

34

29

23

 

 

 

 

 

 

 

 

 

 

High pressure is measured at the liquid service valve ( the smaller valve).

 

 

 

 

 

Amps = Outdoor unit amps (comp.+fan)

Low pressure is measured at the gauge port connection.

 

 

 

 

 

 

 

 

 

kW = Total system power

Calculations are based on nominal CFM and 70 °F indoor dry bulb.

 

 

 

 

 

 

 

 

 

 

20

www.goodmanmfg.com

SS-DSZC18

Page 20
Image 20
Goodman Mfg SS-DSZC18 dimensions Expanded Heating Data, Product Specifications