E
SPECIFICACIONES
DEL
P
RODUCTO

SS-PGBC50-S www.goodmanmfg.com 11

Aire de
Interior Temperatura del Aire del Condensador
75°F 85°F 95°F 105°F 115°F
SCFM WB Total
KBTU/h Sens
KBTU/h kW Total
KBTU/h Sens
KBTU/h kW Total
KBTU/h Sens
KBTU/h kW Total
KBTU/h Sens
KBTU/h kW Total
KBTU/h Sens
KBTU/h kW
3400
72 149.0 71.7 9.95 140.0 66.6 11.27 131.1 61.5 12.59 122.1 56.4 13.91 113.1 51.3 15.23
67 137.5 86.8 9.31 128.6 82.2 10.59 119.8 77.6 11.86 111.0 73.0 13.14 102.1 68.4 14.41
62 125.1 106.6 8.89 119.0 99.7 10.07 113.0 92.8 11.25 106.9 85.9 12.43 100.9 79.0 13.61
57 120.9 115.5 8.54 114.1 106.4 9.78 107.3 97.2 11.01 100.5 88.1 12.24 93.7 79.0 13.47
4000
72 155.4 79.5 10.28 145.7 74.1 11.62 136.1 68.7 12.96 126.4 63.3 14.30 116.7 57.9 15.64
67 142.6 101.8 9.62 133.7 95.5 10.92 124.8 89.2 12.22 115.9 82.9 13.52 107.0 76.6 14.82
62 130.1 124.2 8.95 123.1 114.7 10.29 116.1 105.3 11.62 109.1 95.8 12.95 102.1 86.3 14.29
57 130.1 124.2 8.95 123.1 114.7 10.29 116.1 105.3 11.62 109.1 95.8 12.95 102.1 86.3 14.29
4600
72 159.2 85.4 10.50 149.5 80.1 11.85 139.8 74.9 13.20 130.0 69.6 14.55 120.3 64.3 15.90
67 146.4 114.4 9.86 137.5 107.2 11.17 128.5 100.0 12.48 119.6 92.7 13.78 110.6 85.5 15.09
62 137.5 131.9 9.39 129.9 121.7 10.75 122.2 111.6 12.11 114.6 101.4 13.46 107.0 91.3 14.82
57 137.5 131.9 9.39 129.9 121.7 10.75 122.2 111.6 12.11 114.6 101.4 13.46 107.0 91.3 14.82
Las capacidades de calefacción sensible indicadas se basan en aire entrante a 80ºF con bulbo seco en el serpentín evaporador. Para otras capacidades de calefac-
ción sensible, restar 84 BTU/H cada 100 CFM de aire en el serpentín evaporador por cada grado por debajo de 80ºF ó sumar 84 BTU/h cada 100 CFM de aire en el
evaporador por encima de 80ºF.

DATOS DE CAPACIDAD DE ENFRIAMIENTO (CONT.)

TABLA 2B: PGB120245-5 (UNIDADES INGLESAS)
Aire de
Interior Temperatura del Aire del Condensador
75°F 85°F 95°F 105°F 115°F
SCFM WB Total
KBTU/h Sens
KBTU/h kW Total
KBTU/h Sens
KBTU/h kW Total
KBTU/h Sens
KBTU/h kW Total
KBTU/h Sens
KBTU/h kW Total
KBTU/h Sens
KBTU/h kW
4760
72 219.0 100.8 16.42 205.3 95.6 18.63 191.7 90.4 20.83 178.0 85.1 23.04 164.4 79.9 25.25
67 202.0 121.4 15.36 188.6 117.7 17.50 175.2 113.9 19.63 161.8 110.2 21.76 148.4 106.5 23.89
62 183.8 149.6 14.67 174.5 142.9 16.64 165.2 136.3 18.61 155.9 129.6 20.59 146.6 123.0 22.56
57 177.6 162.6 14.10 167.2 152.7 16.15 156.9 142.8 18.21 146.5 132.9 20.27 136.1 123.0 22.33
5600
72 228.3 111.6 16.97 213.6 106.3 19.21 199.0 100.9 21.45 184.3 95.5 23.68 169.6 90.1 25.92
67 209.5 142.7 15.87 196.0 136.9 18.05 182.5 131.0 20.22 169.0 125.2 22.40 155.5 119.3 24.46
62 191.1 174.8 14.77 180.5 164.7 17.00 169.8 154.6 19.23 159.1 144.5 21.46 148.4 134.4 23.68
57 191.1 174.8 14.77 180.5 164.7 17.00 169.8 154.6 19.23 159.1 144.5 21.46 148.4 134.4 23.68
6440
72 233.9 119.7 17.33 219.1 114.8 19.59 204.4 109.9 21.85 189.6 105.0 24.11 174.9 100.1 26.37
67 215.1 160.4 16.27 201.5 153.6 18.46 187.9 146.8 20.64 174.3 140.0 22.83 160.7 133.2 25.01
62 202.0 185.6 15.49 190.4 174.7 17.76 178.8 163.9 20.03 167.1 153.0 22.30 155.5 142.1 24.57
57 202.0 185.6 15.49 190.4 174.7 17.76 178.8 163.9 20.03 167.1 153.0 22.30 155.5 142.1 24.57
Las capacidades de calefacción sensible indicadas se basan en aire entrante a 80ºF con bulbo seco en el serpentín evaporador. Para otras capacidades de calefac-
ción sensible, restar 84 BTU/H cada 100 CFM de aire en el serpentín evaporador por cada grado por debajo de 80ºF ó sumar 84 BTU/h cada 100 CFM de aire en el
evaporador por encima de 80ºF.
TABLA 3B: PGB180245-5 (UNIDADES INGLESAS)
Aire de
Interior Temperatura del Aire del Condensador
23.9°C 29.4°C 35.0°C 40.6°C 46.1°C
L/S WB Cap.
Total Cap.
Sens kW Cap.
Total Cap.
Sens kW Cap.
Total Cap.
Sens kW Cap.
Total Cap.
Sens kW Cap.
Total Cap.
Sens kW
2246
22.2 64.17 29.53 16.42 60.17 28.00 18.63 56.17 26.48 20.83 52.17 24.95 23.04 48.17 23.43 25.25
19.4 59.19 35.59 15.36 55.27 34.49 17.50 51.35 33.39 19.63 47.42 32.29 21.76 43.50 31.20 23.89
16.7 53.86 43.83 14.67 51.14 41.88 16.64 48.42 39.93 18.61 45.69 37.99 20.59 42.97 36.04 22.56
13.9 52.05 47.66 14.10 49.01 44.75 16.15 45.97 41.85 18.21 42.93 38.94 20.27 39.90 36.04 22.33
2643
22.2 66.90 32.71 16.97 62.61 31.14 19.21 58.31 29.56 21.45 54.01 27.99 23.68 49.71 26.42 25.92
19.4 61.40 41.82 15.87 57.44 40.10 18.05 53.48 38.39 20.22 49.53 36.68 22.40 45.57 34.96 24.57
16.7 56.02 51.22 14.77 52.89 48.26 17.00 49.76 45.30 19.23 46.63 42.34 21.46 43.50 39.38 23.68
13.9 56.02 51.22 14.77 52.89 48.26 17.00 49.76 45.30 19.23 46.63 42.34 21.46 43.50 39.38 23.68
3039
22.2 68.54 35.09 17.33 64.22 33.66 19.59 59.89 32.22 21.85 55.57 30.78 24.11 51.24 29.34 26.37
19.4 63.03 47.01 16.27 59.05 45.02 18.46 55.07 43.02 20.64 51.09 41.02 22.83 47.11 39.03 25.01
16.7 59.20 54.38 15.49 55.79 51.20 17.76 52.38 48.02 20.03 48.98 44.84 22.30 45.57 41.66 24.57
13.9 59.20 54.38 15.49 55.79 51.20 17.76 52.38 48.02 20.03 48.98 44.84 22.30 45.57 41.66 24.57
Las capacidades de calefacción sensible indicadas se basan en aire entrante a 26,7ºC con bulbo seco en el serpentín evaporador. Para otras capacidades de calefac-
ción sensible, restar 44,32 W cada 47 L/S de aire en el serpentín evaporador por cada grado por debajo de los 26,7ºC o sumar 44,32 W cada 47 L/S de aire en el
evaporador por encima de la temperatura mencionada.

TABLA 3A: PGB180245-5 (UNIDADES SI)