SS-SSX16 www.goodmanmfg.com 55
Product SPecificationS

Wiring diAgrAm — SSX160591**

Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
WARNING High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
8 76 5 4 21
3
8 76 5 4 213
E
D
B
A
C
E
D
B
A
C
CONFIDENTIAL PROPERTY OF THE GOODMAN MANUFACTURING COMPANY, L.P. NOT TO BE DISCLOSED TO OTHERS, COPIED, OR USED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING. MUST BE RETURNED UPON DEMAND, ON COMPLETION OF ORDER, OR OTHER PURPOSE FOR WHICH IT WAS LENT.
COMPONENTS AND MATERIALS SPECIFIED HEREIN WILL ALSO CONFORM TO THE APPLICABLE SECTION OF GOODMAN MSP 824.01 WORKMANSHIP
STANDARD FOR FIT, FEEL AND FINISH.
SPECIAL CHARACTERISTICS:
= 6SIGMA = CRITICAL CHARACTERISTIC = SIGNIFICANT CHARACTERISTIC
SC
CC
6s

LABEL, WIRING DIAGRAM

DATE: 02-23-10
ENG: SVDWN BY: GL DO NOT SCALE DRAWING

0140R00166 A

REV
CHK BY: SK SHT 1 OF 1
THE GOODMAN MANUFACTURING COMPANY, L.P.
TOLERANCES:
ANGLES ± 1.5°
.X : ± .1
.XX : ± .03
.XXX : ± .015
HOLE Ø : ± .005
TUBE CUT LG: ± .063
DRAWING TO BE INTERPRETED IN
ACCORDANCE WITH ASME Y14.100
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE NOTED
ECN REV DESCRIPTION CHK DR DATE
1004571 ASK 02-24-10INITIAL RELEASE
ZONE
-GL
USE N.E.C. CLASS 2 WIRE
NO TES :
1) TO INDOOR UNIT LOW V OLTAGE
TERMINAL BLOCK & INDOOR
THERMOSTAT.
2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED.
COMP
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
IO
T1
C
MAIN
R
AUX
5
S
SR
SA
21
RCCF
SC
T2
C
L1 L2
(IF USED)
CH
C
F
MAIN
AUX
C
C
0140R00166 REV A
BL
Y
C
LVJB
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BL/PK ---------- BLUE/PINK STRIPE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
YL/PK ---------- YELLOW/PINK STRIPE
CONTROL BOX
COMPONENT CODE
C --------------- CONTACTOR
CH ------------- CRANKCASE HEATER
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
HPS ----------- HIGH PRESSURE SWITCH
IO -------------- INTERNAL OVERLOAD
LPS ------------ LOW PRESSURE SWITCH
LVJB ---------- LOW VOLTAGE JUNCTION BOX
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
SA ------------- START ASSIST
SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
T1
L1
T2
L2
ALTERNATE DOUBLE
POLE CONTACTOR
OUTDOOR POWER SUPPLY
SEE RATING PLATE
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW V OLTAGE
OPTIONAL HIGH VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW V OLTAGE
IO
CM
Y
PU
BR
BK
MAIN
AUX
CM
IO
BL/PK
YL
C
R
S
RD
BK AUX
MAIN
COMP
NOTE 1
SC
RD BL
RCCF
F
CHE RM
YLYL
YL
BR
RD
PU
YL
RD
SR
5
21
BK
YL
BL
RD
BL
RD
RD
BKBK
BK
C
T1
L1
T2
L2
RD
SA
(IF USED)
NOTE 2
EQUIPMENT GROUND
USE COPPER
CONDUCTORS ONLY
YL/PK LPS
BL/PK HPS BL/PK
YL/PK
LPS
HPS
BK
BK
CH
NOTES:
1. MATERIAL: 4 MIL WHITE FLEXIBLE VINYL WITH PRESSURE SENSITIVE PERMANENT ACRYLIC ADHESIVE AS PER
SPEC S4900061, TYPE A
2. WIRING DIAGRAM TO BE 8" W X 6" H
3. LABEL TO BE BLACK PRINT ON WHITE BACKGROUND