Safety instructions (EN 61010-1)

In order to preclude any danger to the operator, the following instructions should be followed:

a)In case any damage or malfunction is detected, take the unit out of operation without delay.

b)Before disassembling the unit, disconnect all inputs / outputs and the supply voltage. When mounting the unit and the connections, make sure all live components are protected from being touched directly.

c)Comply with the usual regulations and safety provisions for low and high current systems, in particular country-specific safety provisions (e.g. VDE 0100).

d)The maximum admissible potential existing between the pin groups as well as to the external protective conductor must not be exceeded. Refer to the unit´s identification label.

e)When connecting the unit to other devices (e.g. PCs), the connection must be carefully planned. Internal connections in external units (e.g. GND connected to protective earth) may cause excessive voltage potential.

f )

This device must be grounded! For low voltage 12VDC and 24VDC systems use screened cable.

 

Units with a.c. supply voltage must be connected the protective conductor.

g)Make sure that the unit is property mounted before connection and power on !

In order to preclude any damage to the unit, the following items must be taken into account:

The maximum admissible potential between the pin groups must not be exceeded.

This applies in particular to high voltage tests.

Refer to the instruction manual !

Warning: Hazardous live voltage !

WARNING:

There is always hazardous voltage present in certain parts during the operation of electrical equipment.

Non-observance of the safety instructions can result in severe personal injury or damage to property. Only qualified personnel should work on this equipment. The successful and safe operation of this equipment is dependant on proper transport, storage, set-up, installation and careful operation and maintenance.

QUALIFIED PERSONNEL

Are personnel who are familiar with the set-up, installation, commissioning and operation of the product and have the qualifications corresponding to their activities, e.g.:

-Are trained and authorised to energise, de-energise, clear, ground and tag circuits and equipment / systems in accordance with established safety standards.

-Are trained in the proper care and use of protective equipment in accordance with established safety practices.

-Are trained in first aid.

Safety according to EN 61010-1, VDE 0411

CAT III > 150 V [ 300 V

 

Pollution degree

:

2; indoor use; altitude <2000 m; relative humidity <80 % up to 31 °C;

Temperature:

 

5 °C to 40 °C;

Page 2
Image 2
Gossen IPP 144 - 40 GE user manual Safety instructions EN, Qualified Personnel

IPP 144 - 40 G, IPP 144 - 40 GE specifications

The Gossen IPP 144 - 40 GE and IPP 144 - 40 G are advanced portable light meters renowned for their precision and reliability in various lighting conditions. These instruments cater to professional photographers, videographers, and lighting designers seeking accurate light measurements to ensure optimal exposure in their work.

One of the standout features of the Gossen IPP 144 series is its dual measurement capability. The IPP 144 - 40 GE offers both incident and reflected light measurement, allowing users to evaluate light conditions from different perspectives. This flexibility enhances its usability in diverse environments, whether it be for capturing studio portraits or outdoor landscapes.

The device features a large, bright LCD display that ensures clear visibility of readings in any lighting situation. The easy-to-navigate menu allows users to access functions efficiently, streamlining the workflow. The robust construction of the meter guarantees durability, making it suitable for fieldwork and everyday use.

Equipped with sophisticated photo sensors, the Gossen IPP 144 meters are capable of providing highly accurate measurements in both artificial and natural lighting conditions. The range of measurement goes from very low light levels to bright daylight, accommodating a wide variety of scenarios. This adaptability is particularly useful for professionals working across different genres of photography and video production.

Another significant characteristic of the IPP 144 - 40 GE and IPP 144 - 40 G is the built-in memory function. This feature allows users to save specific readings for later analysis, enabling them to compare different lighting setups or conditions. With this capability, photographers can make informed decisions about adjustments to achieve desired aesthetic results.

Additionally, the meters come equipped with a calibration function, ensuring long-term reliability and accuracy. Regular calibration against known standards guarantees that users can depend on the readings delivered by these light meters.

Overall, the Gossen IPP 144 - 40 GE and IPP 144 - 40 G stand out with their combination of advanced measurement capabilities, durable design, and user-friendly interface. They are indispensable tools for professionals who demand precision and versatility in their light measurement equipment, ensuring their creative visions can be realized with confidence in any lighting environment.