PERIODIC MAINTENANCE

ASSEMBLY

Refer to the illustration above and the drawings in the back of this manual for your exact model.

Note: Clean all valve parts with an appropriate solvent prior to reassembly. Always install new, lubricated O-rings and seals when assembling the valve. Use Krytox 203GPL (part number 84/0200-K3/11) for lubricating valve parts including seals and o-rings. Apply a very thin film of lubricant to the inside diameter surfaces of the Top Cylinder Block (17), the outside of the Metering Rod (21) and to the seals and o-rings. Check the Metering Rod/Sleeve Assembly (7) for wear and if it is worn secure a replacement before proceeding.

Note: Use caution as you install new U-cup and Posipak seals so that they are not pinched or torn. Do this by making sure they are lubricated, and by tucking the lips of the seal inward before uniformly pushing them into position.

1.Insert the lubricated Posipak Seal (14) lip side down into the Metering Rod Sleeve (7).

2.Insert the Seal Separator Block (5).

3.Install, in order, the lubricated Posipak Seal (20) lip side up, the lower Washer (16), and the lower Retaining Ring (3).

4.Install the Seal Separator Rod (6), aligning the cross-hole so that the metering rod can pass through it.

5.Insert the Metering Rod (21) carefully through the lower Retaining Ring (3), the lower Washer (16), the Posipak Seal (20), the Seal Separator Block (5), Seal Separator Rod (6) and the Posipak Seal (14).

6.Install the lubricated U-cup Seal (15) lip side down into the Top Cylinder Block (17).

7.Install the upper Washer (16), then the upper Retaining Ring (3).

8.Install the lubricated O-ring (4) on the Piston (2).

9.Install the lubricated O-ring (19) into the Top Cylinder Block (17).

10.Insert the Piston (2) with O-ring (4) part way into the Top Cylinder Block (17) carefully so that the piston threads do not damage the Posipak Seal (14). Position the piston to accept the head of the metering rod.

11.Insert the Metering Rod head (21) into the Piston (2).

12.Screw the Metering Rod/Sleeve Assembly (7) into the Top Cylinder Block (17).

13.Install the lubricated O-ring (9) on the Metering Rod/Sleeve Assembly (7).

14.Install the lubricated O-ring (12) carefully over the threads of the Needle Adapter (10). Note:If the valve has the alternate needle adapter, install the outside O-ring (22).

15.Insert the lubricated O-ring (8) into the Metering Rod/Sleeve Assembly (7). Use a blunt tool to seat the o-ring firmly.

Note: For .188 diameter rod models, first insert the Plastic Washer (8A) into the Metering Rod/Sleeve Assembly (7), followed by the O-ring (8). Then, use a blunt tool to seat the o-ring and washer firmly.

16.Insert the Check Valve Poppet (13) into the Check Valve Spring (11). Insert the check valve poppet/spring assembly into the Needle Adapter (10).

17.Screw the needle adapter/check valve spring/poppet assembly firmly into the Metering Rod/Sleeve Assembly (7).

18.Screw on the Stroke Adjustment Collar (1).

19.Tighten the Socket Head Set Screw (18).

20.Mount the valve and connect the air lines. If your valve is equipped with optional cycle detection, install the sensors and tighten the set screws.

The model 1206 Dispense Valve is now ready to be placed back into service.

Page 8

Page 8
Image 8
Graco 1206 important safety instructions Assembly

1206 specifications

The Graco 1206 is a leading product in the realm of airless paint sprayers, designed for both professionals and DIY enthusiasts. Known for its robust construction and user-friendly features, the Graco 1206 offers an exceptional painting experience, making it a go-to choice for a variety of applications, from small projects to larger jobs.

One of the standout features of the Graco 1206 is its powerful motor, which provides consistent pressure and a smooth spray pattern. This motor ensures optimal performance, allowing users to cover large areas efficiently without compromising on quality. The unit's adjustable pressure settings enable users to tailor the flow of paint according to the specific requirements of their project, accommodating both thin and thick coatings.

In addition to its motor, the Graco 1206 is equipped with advanced technology that enhances usability. The flexible suction tube lets users spray directly from a 1-gallon or 5-gallon bucket, minimizing the need for frequent refills and allowing for uninterrupted work sessions. This convenient feature, combined with the quick-change tip system, simplifies the process of switching between different paint types and spray patterns.

The Graco 1206 also boasts a durable and lightweight design. Constructed from high-quality materials, it is built to withstand the rigors of job site use while remaining portable enough for easy transport. The unit's ergonomic handle and wheeled design further enhance mobility, making it easy to maneuver around various work environments.

Safety is another key consideration in the design of the Graco 1206. The machine incorporates a built-in filter that helps to prevent paint clogs, while the innovative no-drip design minimizes mess during operation. Additionally, the Graco 1206 is compatible with a range of accessories, offering users the flexibility to customize their painting setup based on individual needs.

In summary, the Graco 1206 is a high-performance airless paint sprayer that combines power, convenience, and durability. Its impressive features, including adjustable pressure settings, flexible suction tube, and lightweight construction, make it an excellent choice for anyone looking to achieve professional-quality painting results with ease. Whether tackling interior renovations or exterior projects, the Graco 1206 consistently delivers outstanding performance and reliability.