![Instructions](/images/new-backgrounds/65142/651421x1.webp)
Instructions
Hopper Kit for GH5040ES, GH733ES, | 332234A | |
GH933, and GH933ES Big Rig Sprayers | EN | |
Model 16U505 |
|
|
Series | Maximum Working Pressure |
|
GH733ES Bare | 4000 psi (27.6 MPa, 276 bar) |
|
GH5040ES Bare | 5000 psi (34.5 MPa, 345 bar) |
|
GH933ES Bare | 7250 psi (50.0 MPa, 500 bar) |
|
GH933 Bare | 7250 psi (50.0 MPa, 500 bar) |
|
IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions in sprayer manual. Save these instructions.
Related Manuals:
332156
332157332158
ti20999a
Pressure Relief Procedure
System pressure must be manually relieved to prevent it from starting or spraying accidentally. Fluid under high pressure can be injected into the skin and cause serious injury. To reduce risk of injury from injection, follow this procedure whenever you are instructed to relieve pressure, stop spraying, service equipment or install or clean spray tip. Read warnings, in operation manual.
1.Set pump valve OFF. Turn engine OFF.
2.Turn pressure to lowest setting. Trigger gun into pail to relieve pressure.
3.Rotate handle
If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, VERY SLOWLY, loosen tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Then clean tip and hose.