15307906
Performance Curves0
25
50
75
100
125
150
012345
(3.8) (7.6) (11.4) (15.1) (18.9)
FLUID FLOW----gpm (lpm)
Test Fluid: No. 10 weight oilat 75_F ( 23.9_C)
To find fluid outlet pressure at a specific fluid f low
and operating air pressure:
1. Locate desired fluid flow along bot tom of chart.
2. Follow vertical line up to int ersection with
selected fluid outlet pressure curve(black).
3. Follow left to sc ale to read fluid outlet pressure.
To find pumpair consumption at a specific fluid
flow and air pressure:
1. Locate desired flow along bott om of chart.
2. Read vertical line up to inter section with
selected air consumption curve (gray).
2. Follow right to scale t o read air consumption.
Air
Consumption
scfm
(m#/min)
KEY black curves=fluid outlet pressure
gray curves=air consumption
(0.34, 3.4)
(0.7, 7)
(0.51, 5.1)
(0.85, 8.5)
4
(0.112)
10
(0.280)
(1.0, 10.4)
2
(0.056)
6
8
(0.224)
A40 psi (0.28 MPa, 2.8 bar) air pressure
B70 psi (0.48 MPa, 4.8 bar) air pressure
C100 psi (0.7 MPa, 7 bar) air pressure
D150 psi (1.0 MPa, 10.4 bar) air pressure
(0.17, 1.7)
B
C
D
(0.168)
A
B
D
C
A
Fluid
OutletPressure,
psi
(MPa, bar)