5307906
Installation
F
BCD
E
KEY
AAir shutoffvalve
BAir filter
CAir regulatorand gauge
DAir motorlubricator
EBleed-typemaster air valve (required, Part No. 110223)
FAir and fluidhose kits
GGround wire(required, Part No. 222011)
HFluid shutoffvalve
Main Air Line
Main FluidLine
AA
GG
H
J
K
L
M
JWallbracket
KUniversalpump (Model222051)
LSuction kit
M55-gallondrum bung-mount pump (Model 222103)
NFluid drain valve (required, Part No. 210658)
PAir inlet
QBall valve (forreleasing collected moisture)
RThermal reliefkit (required for permanent
installations,Part No. 237601)
28 Bung adapter
Fig. 1
BCD E F
N
N
PP
28
Q
Q
R
H
R
05942B
Install the accessories in the order shown in the typic al installation in Fig. 1. The installation shown in Fig. 1 is only
a guide for selecting and installing a pump; it is not an actual system design. Contact your G racor epresentative for
assistance in designing a system to suit your needs.
NOTE: Blow out all lines with compressed air before you connect the pumps.
Always mount the pump firmly to a wall bracket or
a bung on a drum. Never operate the pump while it
is not mounted. Such use could damage the pump
and fittings.
CAUTION CAUTIONDo not hang the air accessories directly on the air
inlet (P). The fittings are not strong enough t o
support the accessories and may break. Provide a
bracket on which to mount the accessories.