Hydraulic Control Module for Custom Tank Installation

(Unless otherwise indicated, see FIG. 5 and FIG. 6, page 9)

1.Mount control module on a flat, sturdy surface per the recommended configuration (Fig. 2, page 8).

2.Connect Pump Tank Line (G) to pump hydraulic outlet port.

3.Connect Vent Valve Hydraulic Control (J) connection to the hydraulic control line (A).

4.Connect the Pump High Pressure Hydraulic Line

(H) to the pump hydraulic input port.

5.Connect high pressure hydraulic supply to the High Pressure Hydraulic Connection (L) and the tank lines to the Hydraulic Tank Connection (K).

6.Connect the 3-way Solenoid Valve (P) to the timer.

Coil should always be installed with lettering facing out.

Installation

Hydraulic Control Module 247705

(For Single-line, Progressive, Automatic Lubrication Systems with refinery reservoir installation)

(Unless otherwise indicated, see FIG. 5 and FIG. 6, page 9)

1.Mount control module on a flat, sturdy surface. The 6-foot hydraulic supply and hydraulic tank line must reach the pump when installed in the refinery reservoir.

2.Connect Pump Tank Line (G) to pump hydraulic outlet port.

3.Remove Vent Valve Hydraulic Control (J) and add plug (R) to vent port.

4.Connect the Pump High Pressure Hydraulic Line

(H) to the pump hydraulic input port.

5.Connect high pressure hydraulic supply to the High Pressure Hydraulic Connection (L) and the tank lines to the Hydraulic Tank Connection (K).