Cleanup
11.Turn pressure control knob all the way down and power switch OFF. Unplug sprayer.
ti5316a
Power Flush™
Power flushing is a faster method of flushing. It can only be used after spraying
/.
/&&
ti20417a
ti4296a
12.Remove filter from gun if installed. Clean and inspect. Install filter. See gun manual.
13.If flushing with water, flush again with mineral spirits or Pump Armor to leave a protective coating to pre- vent freezing or corrosion.
This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Pro- cedure when you stop spraying and before cleaning, checking, or servicing the equipment.
1.Perform Relieve Pressure Procedure, page 6.
2.Remove guard and spray tip. For additional informa- tion, see gun manual.
ti2895a
14.Wipe sprayer, hose and gun with a rag soaked in water or mineral spirits.
ti2783a
15. Insert suction tube into cup to catch any drips.
ti20403a
ti20408a
3.Remove siphon tube set from paint. Wipe excess paint off outside of tubes.
4.Unscrew inlet strainer from suction tube. Place inlet screen in waste pail.
ti9433a
5.Screw shutoff valve onto garden hose. Turn lever and open valve.
ti9412a
12 | 332161A |