Pressure Relief Procedure

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever you see this symbol.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Pro- cedure when you stop spraying and before cleaning, checking, or servicing the equipment.

1. Turn pressure control to lowest pressure.

3.Turn prime valve down. If you suspect spray tip or hose is clogged or pressure is not fully relieved, VERY SLOWLY loosen tip guard retaining nut or hose end coupling to relieve pressure. Then loosen completely.

ti20406a

4.Turn power switch OFF, if unit is being shut down or will be left unattended.

ti5316a

ti20417a

2.Hold gun against side of grounded metal flushing pail. Trigger gun to relieve pressure.

ti20417a

/.

/&&

6

332161A

Page 6
Image 6
Graco 262906 important safety instructions Pressure Relief Procedure